Skip to content

What are you looking for?


You may also like

1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller
1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller
1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller
1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller

1756-L81ES | Allen-Bradley | ControlLogix GuardLogix 5580 Safety Controller


Only 10 left - Selling fast

PRODUCT SKU : 1756-L81ES

PRODUCT TYPE : Safety Controller

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1756-L81ES functions as a high-performance SIL 3/PLe capable processor within the ControlLogix 5580 family. This GuardLogix controller provides a unified solution for both standard and safety-critical control tasks, executing complex safety logic alongside general automation processes. We supply this unit as 100% Brand New and Original, ensuring your system benefits from the high-speed 1Gbps Ethernet port and the latest security firmware essential for modern smart manufacturing environments.

Technical Specifications

Feature Specification Details
User Memory 3 MB
Safety Memory 1.5 MB
Nonvolatile Memory 2 GB (Ships with secure SD card)
Ethernet Speed 10 / 100 / 1000 Mbps (Gigabit)
Maximum I/O Points 128,000
Maximum Ethernet Nodes 100
Safety Languages Ladder Diagram (LD) Only
Standard Languages LD, ST, FBD, SFC
Power Dissipation 6.2 Watts
Weight 0.94 lbs (0.43 kg)

Engineering Advantages

  • Integrated Safety and Motion: The 1756-L81ES eliminates the need for a separate safety partner for many SIL 2 applications, reducing chassis space and hardware costs. It manages high-speed integrated motion over EtherNet/IP, allowing engineers to synchronize safety functions directly with servo drive performance.

  • Gigabit Performance for Data-Intensive Loads: The onboard 1Gbps Ethernet port facilitates rapid data exchange between the CPU and up to 100 nodes. This high bandwidth prevents network bottlenecks when executing complex safety interlocking across distributed I/O systems.

  • Strict Safety Logic Enforcement: To maintain the highest integrity, the controller restricts safety tasks to Ladder Diagram (LD) only. This ensures that safety logic remains easy to audit and verify during third-party safety inspections or risk assessments.

  • Energy-Efficient Thermal Design: With a low power dissipation of 6.2W, the 1756-L81ES minimizes heat buildup within the ControlLogix chassis. This design extends the lifespan of adjacent modules and allows for reliable operation in enclosures where airflow is limited.

FAQs

Q: Can I use Structured Text (ST) for safety logic in the 1756-L81ES? A: No. While the 5580 GuardLogix supports multiple languages for standard tasks, safety tasks strictly require Ladder Diagram (LD). This limitation ensures maximum visibility and adherence to safety programming standards.

Q: Is this unit a "Refurbished" or "Used" surplus module? A: Absolutely not. We guarantee this 1756-L81ES is 100% Brand New and Original. It ships in the manufacturer’s original factory-sealed box, which is critical for safety-rated components where operational history and component fatigue are major factors.

Q: Does this controller require a Safety Partner module? A: The 5580 series controllers, such as the 1756-L81ES, provide an "integrated" safety solution. For many SIL 2 applications, you do not need a separate safety partner, though high-level SIL 3 requirements may still dictate specific architecture configurations in Studio 5000.

Q: How do I backup the program without a permanent PC connection? A: The module includes a 2GB nonvolatile memory card. You can configure the controller to load the program from this SD card automatically upon power-up, ensuring the machine resumes operation immediately after a power cycle or CPU replacement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more