Skip to content

What are you looking for?


You may also like

Foxboro FBM215/218 RH926SP HART Communication Output Interface ModuleFoxboro FBM215/218 RH926SP HART Communication Output Interface ModuleFoxboro FBM215/218 RH926SP HART Communication Output Interface Module
Foxboro FBM215/218 RH926SP HART Communication Output Interface Module
Foxboro FBM215/218 RH926SP HART Communication Output Interface Module
Foxboro FBM215/218 RH926SP HART Communication Output Interface Module

Foxboro FBM215/218 RH926SP HART Communication Output Interface Module


Only 10 left - Selling fast

PRODUCT SKU : FBM215/218 RH926SP

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for isolated analog and digital signal execution in distributed control systems, the Foxboro FBM215/218 RH926SP (FBM215/218 RH926SP) HART Communication Output Interface Module provides direct physical/electrical execution. The unit processes control logic into 8 isolated output channels combining analog control streams with superimposed digital HART diagnostics.

Hardware Specifications

Parameter Specification
Model FBM215/218 RH926SP
Brand Foxboro
Weight Approx. 0.4 lbs (0.18 kg)
Dimensions Standard Modular FBM Enclosure
Operating Temp -20 deg C to +70 deg C (-4 deg F to 158 deg F)
Power Consumption Powered via system backplane bus
Output Channels 8 isolated outputs
Signal Type 4-20 mA analog + HART FSK digital overlay
Vibration Resistance 7.5 m/s2 (0.75 g), 5 to 500 Hz

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

Within process control installations, this interface module manages communication links using the 4-20 mA HART loop protocol to transmit real-time control variables alongside two digital diagnostic messages per second per channel. Internal board architecture implements strict channel-to-channel isolation and galvanic barriers across each output path, eliminating ground loops, suppressing electromagnetic interference, and protecting internal controller logic from external field transients.

Frequently Asked Questions

Q: Does the FBM215/218 RH926SP module support hot-swapping on a powered Foxboro mounting base?

N/A: Yes, the module design permits live insertion and removal on an active baseplate without interrupting neighboring slot communications, provided standard system maintenance procedures are followed.

Q: How does the module handle communication errors on the HART FSK digital overlay?

N/A: The hardware processes parity checks and transmission acknowledgments internally, flagging communication faults to the primary controller if loop impedance or signal attenuation exceeds tolerance thresholds.

Field Installation Guidelines

  • Mount the module securely into the designated slot on an approved Foxboro mounting structure, ensuring complete mechanical engagement with backplane connector pins.
  • Terminate all field signal wiring using shielded twisted-pair cables, grounding the shield drain wire exclusively at the cabinet ground busbar to prevent ground loops.
  • Verify that ambient temperatures within the instrumentation cabinet remain strictly within the -20 deg C to +70 deg C operational envelope.
  • Check that field loop power supplies are correctly matched to the output channel voltage requirements prior to energizing the circuit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more