Skip to content

What are you looking for?


You may also like

ABB CB801 3BSE042245R1 PROFIBUS DP Communication ModuleABB CB801 3BSE042245R1 PROFIBUS DP Communication ModuleABB CB801 3BSE042245R1 PROFIBUS DP Communication Module
ABB CB801 3BSE042245R1 PROFIBUS DP Communication Module
ABB CB801 3BSE042245R1 PROFIBUS DP Communication Module
ABB CB801 3BSE042245R1 PROFIBUS DP Communication Module

ABB CB801 3BSE042245R1 PROFIBUS DP Communication Module


Only 10 left - Selling fast

PRODUCT SKU : CB801 3BSE042245R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB CB801 3BSE042245R1, also cataloged as the CB801 PROFIBUS DP Communication Module, operates as a dedicated hardware component for fieldbus data exchange within Panel 800 control platforms.

Hardware Specifications

Parameter Specification
Model CB801 (3BSE042245R1)
Brand ABB
Origin Sweden / Germany
Weight 0.2 kg
Dimensions 121.5 mm x 49.5 mm x 153 mm
Operating Temp -20 deg C to +70 deg C
Power Consumption Varies based on fieldbus transceiver load
Product Type Communication Expansion Module
Communication Protocol PROFIBUS DP Slave
Baud Rate 9.6 kbps to 12 Mbps
Fieldbus Interface RS-485 serial hardware connection

Deterministic Network Backplane and System Signal Integrity

The CB801 expansion module establishes cyclic slave data exchange across PROFIBUS DP deterministic networks at baud rates up to 12 Mbps. Interfacing via an RS-485 serial architecture, the internal communication logic coordinates cyclic I/O data frames with minimal backplane latency.

The hardware architecture provides galvanic isolation along the fieldbus interface to prevent ground potential loops and suppress transient surge coupling. Full firmware flash compatibility ensures seamless integration with Panel 800 operator hardware without interrupting local backplane bus communication velocity.

Frequently Asked Questions

Q: Does the CB801 module automatically match the PROFIBUS DP master baud rate?

A: Yes, the onboard PROFIBUS controller performs automatic baud rate detection from 9.6 kbps up to 12 Mbps upon network initialization.

Q: Can the CB801 module be installed while the host Panel 800 terminal remains powered?

A: No, the host terminal must be completely powered down prior to inserting or removing the CB801 expansion module from the interface bay.

Q: What physical bus medium is required to connect the CB801 to the fieldbus network?

A: Connections must be made using standard shielded twisted-pair cable complying with PROFIBUS DP RS-485 physical layer specifications.

Field Installation Guidelines

  • De-energize all primary power supplies to the Panel 800 terminal before inserting the module into the expansion slot.
  • Attach a grounded wrist strap to prevent electrostatic discharge when handling the internal module PCB and connector pins.
  • Slide the CB801 module straight into the dedicated slot until the multi-pin backplane connector seats completely.
  • Fasten all mechanical retaining screws to ensure proper grounding continuity through the chassis enclosure.
  • Route PROFIBUS DP cables away from high-voltage AC lines and VFD output wiring to maintain communication signal integrity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more