Product Details

The ABB 560ETH02 1KGT009200R0001, also cataloged as the 560ETH02 Ethernet Communication Module, operates as a dedicated hardware component for network interface bridging and Ethernet data routing within ABB RTU560 platforms.

Hardware Specifications

Parameter Specification
Model 560ETH02 1KGT009200R0001
Brand ABB
Origin Germany
Operating Temp -40 to +70 deg C
Power Consumption 2 W Typical
Power Supply 5 VDC via Backplane Bus
Communication Interface 2 x Ethernet Network Ports
Target System ABB RTU560 System Subracks

Deterministic Network Integration and I/O Density Scaling

The 560ETH02 interface card facilitates dual-port packet switching across Profinet and EtherNet/IP deterministic networks, enabling parallel communication channels directly from the RTU backplane. Optimized internal bus decoding maintains high backplane bus communication velocity to minimize packet conversion latency during intensive telecontrol polling routines. Compact subrack form-factor design preserves I/O density scaling inside subrack frames, while onboard flash memory guarantees full firmware flash compatibility during remote system maintenance and software revision updates.

Frequently Asked Questions

Q: How does the 560ETH02 draw operational logic power inside the RTU rack?

A: Power is supplied directly at 5 VDC through the system backplane connector, consuming 2 W under typical operational loads without requiring external DC wiring.

Q: Are the two Ethernet ports on the front panel individually configurable?

A: Yes, the dual Ethernet ports support independent network node addresses to enable redundant network topologies or distinct LAN segment routing.

Q: What environmental thermal thresholds must be observed during enclosure layout?

A: Operating temperature range is -40 to +70 deg C. Adequate natural convection cooling must be maintained across the subrack slots to avoid thermal throttling.

Field Installation Guidelines

  • Verify that subrack power is completely turned off before inserting or removing the 560ETH02 module from the backplane guide rails.
  • Use industrial-grade shielded Category 5e or Category 6 Ethernet cables with RJ45 metal-shielded connectors.
  • Ground cable shields to the main cabinet earth rail to mitigate high-frequency electromagnetic interference.
  • Tighten the module top and bottom retaining screws to ensure continuous chassis grounding contact with the subrack frame.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more