ABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet ModuleABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet ModuleABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet Module
ABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet Module
ABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet Module
ABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet Module

ABB 1MRK002266-BAr02 Protection and Control Accessories Optical Ethernet Module


Only 10 left - Selling fast

PRODUCT SKU : 1MRK002266-BAr02

PRODUCT TYPE : Optical Ethernet Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 1MRK002266-BAr02, also cataloged as the 1MRK002266-BA Optical Ethernet Module, operates as a dedicated hardware component for high-speed fiber optic data transmission within Grid Automation and Protection and Control IED platforms. The unit converts internal electrical communication buses into dual glass optical channels to transmit network packets with total immunity to electromagnetic interference (EMI).

Hardware Specifications

Parameter Specification
Model 1MRK002266-BAr02
Brand ABB
Product Type Optical Ethernet Modules
Interfaces 2 glass fiber optic interfaces
Net Weight 0.1 kg
Dimensions Standard IED communication card plug-in form factor
Operating Temp -10 to +55 deg C (standard IED panel ambient)
Power Consumption Powered via IED internal auxiliary bus

Profinet / EtherNet/IP Deterministic Networks and Firmware Flash Compatibility

The module integrates dual glass fiber optic ports designed for high-density packet throughput across Profinet and EtherNet/IP deterministic networks. By routing deterministic control traffic over optical media, the interface eliminates ground potential shifts and galvanic noise coupling between distant subracks. Integrated firmware flash compatibility guarantees continuous synchronization with the host protection IED processing unit, preventing packet jitter during high-speed sampled value and GOOSE message transmissions.

Frequently Asked Questions

Q: Does inserting or removing the optical Ethernet module require de-energizing the host IED?

A: Power to the protection IED must be isolated before installing or removing the module to prevent electrical stress on internal backplane pin headers.

Q: How do the two glass fiber interfaces handle network line disruptions?

A: When configured within redundant network topologies (such as PRP or HSR protocols), the dual glass fiber ports process simultaneous duplicate frames to maintain zero-switchover-time network recovery.

Field Installation Guidelines

  1. Module Insertion: Slide the optical module carefully into the designated communication slot on the rear panel of the protection IED until the front faceplate flushes against the chassis frame.
  2. Fastener Securing: Tighten the retaining thumbscrews manually or with a standard screwdriver to establish solid mechanical grounding between the module faceplate and IED enclosure.
  3. Fiber Cable Cleanliness: Inspect and clean glass fiber connector end-faces using isopropyl alcohol wipes before insertion into the optical transceivers.
  4. Bending Radius Constraints: Observe minimum bending radius limits (typically 30 mm minimum) for optical fiber jumpers inside cabinet trunking to avoid signal attenuation or glass core fracture.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more