PRODUCT SKU : DS200RTBAG3AHC

PRODUCT TYPE : Digital I/O Cards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE DS200RTBAG3AHC, also cataloged as the DS200RTBA Relay Terminal Card, operates as a dedicated hardware component for contact-based signal distribution and drive excitation control within EX2000 systems.

Hardware Specifications

Parameter Specification
Model DS200RTBAG3AHC
Brand General Electric
Origin USA
Operating Temp 0 to 60 deg C
Core Components 10 relays (K20-K29), 52 terminal points

Industrial Control & Firmware Compatibility

The DS200RTBAG3AHC utilizes a hard-wired relay matrix to execute discrete logic switching. Deterministic control is maintained via local pilot relay activation or remote logic inputs, ensuring synchronized response across the I/O bus. The board supports high-density I/O scaling through its 52 terminal points, which provide configurable Normally Open (NO) and Normally Closed (NC) contact states. Firmware flash compatibility is not applicable to this terminal board, as all signal logic is implemented via physical electromechanical contact configurations (DPDT for K20-K26, 4PDT for K27-K29). Backplane power distribution is managed through dedicated CPH (positive) and CPN (negative) stab connectors, which supply potential to pluggable circuits C1PL-C5PL and Y9PL-Y37PL.

Frequently Asked Questions

Q: Are the relays K20-K26 and K27-K29 interchangeable?

A: No. The relay types utilize distinct contact configurations and current ratings. K20-K26 are DPDT 10 A units, while K27-K29 are 4PDT 1 A units. Replacement must match the specific part number requirements for each relay location to maintain circuit integrity.

Q: How is control power applied to the pluggable circuits?

A: Control power is introduced via the CPH and CPN stab connectors. CPH functions as the positive terminal and CPN as the negative. Ensure these connections are secure before energizing the pluggable circuit paths C1PL-C5PL or Y9PL-Y37PL to avoid arcing or intermittent contact.

Field Installation Guidelines

  • Terminal Identification: Verify all 52 signal wires against the cabinet wiring schematic before landing. Ensure that the K20 Form C contact series is correctly mapped to the intended Normally Open or Normally Closed positions.
  • Torque Requirements: Tighten terminal block screws to manufacturer-recommended torque values to prevent high-resistance connections, which can lead to overheating during sustained relay operation.
  • Connector Seating: Ensure the CPH and CPN stab connectors are fully engaged. Loose stab connections in high-vibration excitation environments can result in intermittent control power loss.
  • Environmental Limits: Maintain the cabinet internal temperature between 0 and 60 deg C. Exceeding these limits can affect the coil pick-up voltages and reduce the operational lifespan of the electromechanical relays.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more