Skip to content

What are you looking for?


You may also like

Bently Nevada 3800A03-50-00 Industrial Monitoring System ModuleBently Nevada 3800A03-50-00 Industrial Monitoring System ModuleBently Nevada 3800A03-50-00 Industrial Monitoring System Module
Bently Nevada 3800A03-50-00 Industrial Monitoring System Module
Bently Nevada 3800A03-50-00 Industrial Monitoring System Module
Bently Nevada 3800A03-50-00 Industrial Monitoring System Module

Bently Nevada 3800A03-50-00 Industrial Monitoring System Module


Only 10 left - Selling fast

PRODUCT SKU : 3800A03-50-00

PRODUCT TYPE : Vibration Monitors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for vibration and shaft position acquisition in Bently Nevada monitoring platforms, the Bently Nevada 3800A03-50-00 (3800A03 Industrial Monitoring Module) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

Option Field Code Configuration Detail
Main Module Base 3800A03 Standard 3800 Series industrial vibration monitoring core architecture
Channel Configuration 50 50-series hardware and signal input options
Agency / Option Code 00 Standard uncertified configuration / baseline options

Hardware Specifications

Parameter Specification
Model 3800A03-50-00
Brand Bently Nevada
Origin USA
Weight 1.2 kg
Dimensions 190 cm x 16.2 cm x 10.8 cm
Operating Temp -20 deg C to +65 deg C
Power Consumption Powered via system backplane assembly
Measurements Dynamic vibration and shaft position telemetry
Outputs Configurable alarm thresholds, discrete relay outputs
Data Handling Real-time acquisition and signal analysis

Rotor Dynamics and Signal Conditioning Execution

The 3800A03-50-00 module executes real-time dynamic signal acquisition from proximity probes and seismic velocity transducers to analyze rotor dynamics across rotating machinery. Internal analog-to-digital processing calculates peak vibration amplitudes and shaft centerline displacement. Integrated output logic monitors signal limits against user-configurable alarm thresholds, driving physical relay contact state execution for machinery protection systems while maintaining low channel-to-channel cross-talk.

Frequently Asked Questions

Q: How are alarm thresholds and physical relay outputs controlled within the 3800A03-50-00?

A: Alarm logic monitors incoming raw analog signals continuously against digitally programmed setpoints. When thresholds are breached, internal dry-contact relays switch state to trigger external safety interlocks or annunciators.

Q: Can the module be inserted or removed while the rack backplane is energized?

A: Rack power should be turned off before inserting or pulling the module to prevent electrical transients across backplane signal connectors and preserve internal calibration settings.

Field Installation Guidelines

  1. Power down the system rack before inserting the 3800A03-50-00 module into its designated rack slot.
  2. Align the module card edges carefully with the top and bottom chassis guide rails inside the enclosure.
  3. Slide the unit inward until the rear edge connector fully seats into the backplane socket.
  4. Secure the front panel retaining screws using appropriate hand tools to ensure solid chassis frame grounding.
  5. Terminate transducer wiring with shielded twisted-pair cables, bonding cable shields to system ground at one end only to prevent ground loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more