Configured for distributed substation communication in M1 automation platforms, the Bachmann FS221/N (FS221/N FASTBUS Slave Module) provides direct physical/electrical execution of high-speed data transmission and auxiliary power distribution to local I/O nodes.

Hardware Specifications

Parameter Specification
Model FS221/N
Brand Bachmann
Origin Austria
Weight 0.45 kg
Dimensions 110 mm x 119 mm x 61 mm
Operating Temp -30 deg C to 60 deg C
Power Consumption 18.25 W (nominal output)
Fiber Port 1x LC (50/125 um or 62.5/125 um)
Max Distance 2000 m (station to station)
Output Supply 5 VDC (3000 mA), +15 VDC (250 mA), -15 VDC (200 mA)

Profinet / EtherNet/IP Deterministic Networks

The FS221/N interfaces with the M1 backplane to facilitate deterministic communication between the primary controller and remote SubDevices. The module supports I/O density scaling by providing an integrated power supply, allowing for the connection of local I/O modules without additional power hardware. Backplane bus communication velocity is optimized for fiber-optic transmission at 1310 nm, ensuring that the 2000-meter span maintains signal integrity within the 8 dB link budget. Firmware flash compatibility is supported, ensuring the communication stack remains compliant with current system firmware for stable long-distance data exchange.

Frequently Asked Questions

Q: Does the integrated power supply support the full 18.25 W load across all output voltages simultaneously?

A: The total nominal output power is 18.25 W. Ensure the combined current draw on the 5 V, +15 V, and -15 V rails does not exceed the specified individual output limits and the total power envelope.

Q: Is this module compatible with single-mode fiber-optic cables?

A: No, the FS221/N is strictly designed for multi-mode fiber (50/125 um or 62.5/125 um) operating at 1310 nm. Using single-mode fiber may result in link budget violations and communication errors.

Q: Can the FS221/N be used in environments with temperatures as low as -30 deg C?

A: Yes, the module is rated for operation in ambient temperatures ranging from -30 deg C to +60 deg C, provided that relative humidity remains between 5% and 95% without condensation.

Field Installation Guidelines

  1. Fiber Termination: Utilize LC connectors and ensure fiber faces are cleaned according to industry standards before insertion. Avoid sharp bends in the fiber cable to stay within the 8 dB link budget.
  2. Mounting: Secure the module to the DIN-rail or mounting surface. Ensure adequate airflow around the unit to dissipate heat generated by the integrated power supply.
  3. Power Wiring: Connect the 24 VDC (18-34 V range) input to the terminal block using adequately sized wire to prevent voltage drops. Verify polarity before energizing.
  4. Shielding: Ensure the chassis is connected to a common system functional earth (FE) to minimize the impact of electromagnetic interference on the optical transceiver electronics.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more