Skip to content

What are you looking for?


You may also like

DIO248 | Bachmann | Digital Input/Output ModuleDIO248 | Bachmann | Digital Input/Output ModuleDIO248 | Bachmann | Digital Input/Output Module
DIO248 | Bachmann | Digital Input/Output Module
DIO248 | Bachmann | Digital Input/Output Module
DIO248 | Bachmann | Digital Input/Output Module

DIO248 | Bachmann | Digital Input/Output Module


Only 10 left - Selling fast

PRODUCT SKU : DIO248

PRODUCT TYPE : Digital Input/Output Modules

PRODUCT VENDOR : Bachmann


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed digital signal processing and counter/encoder interface tasks in M1 automation platforms, the Bachmann DIO248 (DIO248 Digital Input/Output Module) provides direct physical/electrical execution of signal monitoring and pulse counting.

Hardware Specifications

Parameter Specification
Model DIO248
Brand Bachmann
Origin Austria
Weight 0.28 kg (approx.)
Dimensions 102 mm x 12 mm x 130 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption 3.0 W
Digital Inputs 16 to 32
Input Voltage (H) 15 to 34 VDC
Input Voltage (L) 0 to 5 VDC
Input Delay 600 us (standard), 10 us to 270 ms (settable)
Max Input Frequency 50 kHz (one-channel)

Profinet / EtherNet/IP Deterministic Networks

The DIO248 module integrates into the M1 rack backplane to facilitate deterministic data exchange between field sensors and the controller CPU. The architecture supports I/O density scaling, allowing the configuration of multiple modules within a single rack to accommodate complex machine automation requirements. Firmware flash compatibility ensures that the counter and interrupt handling algorithms remain synchronized with the platform-specific I/O drivers. The backplane bus communication velocity is optimized to ensure that time-critical interrupt signals are processed with minimal jitter, maintaining deterministic response times for frequency measurement and gate control tasks.

Frequently Asked Questions

Q: Are the 8 interrupt inputs capable of handling high-speed encoder pulse trains?

A: Yes, these inputs are configurable for incremental encoder interfaces (A/B channels) and support pulse evaluation modes up to 20 kHz for dual-channel setups.

Q: Can the input delay be adjusted per channel, or is it global for the module?

A: The input delay is settable within the specified range of 10 us to 270 ms, allowing for per-channel or group-based optimization depending on the signal source characteristics.

Q: Does the module support hot-swapping under load?

A: No, the DIO248 does not support live hot-swapping. Ensure the system power is removed before inserting or extracting the module to prevent backplane damage or communication bus errors.

Field Installation Guidelines

  1. Wiring: Use shielded cables for all digital inputs, particularly for high-frequency encoder signals, to prevent electromagnetic interference (EMI). Connect the shield to the module's functional earth terminal.
  2. Signal Separation: Maintain clear physical separation between high-speed signal wiring and 24 VDC power distribution lines to prevent induced noise on the 8 kOhm input circuits.
  3. Grounding: Ensure the M1 rack backplane is connected to a low-impedance earth grid. Stable grounding is mandatory for reliable signal evaluation at 50 kHz input frequencies.
  4. Connector Seating: Verify that the front connector is properly seated and the locking mechanism is engaged to maintain connection integrity for all 32 input channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more