Skip to content

What are you looking for?


You may also like

Bachmann RS204 Interface ModuleBachmann RS204 Interface ModuleBachmann RS204 Interface Module
Bachmann RS204 Interface Module
Bachmann RS204 Interface Module
Bachmann RS204 Interface Module

Bachmann RS204 Interface Module


Only 10 left - Selling fast

PRODUCT SKU : RS204

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Bachmann


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multi-protocol serial communication in M1 automation platforms, the Bachmann RS204 (RS204 Interface Module) provides direct physical/electrical execution of high-speed data exchange across four asynchronous serial ports.

Hardware Specifications

Parameter Specification
Model RS204
Brand Bachmann
Origin Austria
Weight 0.25 kg
Dimensions 102 mm x 12 mm x 130 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption 2.8 W
Interface Ports 4 channels
Max Baud Rate 1.5 MBaud
Protocols RS232, RS422, RS485

Profinet / EtherNet/IP Deterministic Networks

The RS204 module interfaces with the M1 rack backplane to facilitate deterministic network connectivity between field devices and the controller CPU. By utilizing optimized backplane bus communication velocity, the module maintains low-latency data throughput even when utilizing all four channels at maximum baud rates. The architecture supports I/O density scaling, allowing for multiple RS204 modules to be integrated into a single rack to accommodate complex multi-node serial topologies. Firmware flash compatibility is supported, ensuring the communication stack and hardware drivers remain synchronized with platform-wide firmware updates to guarantee deterministic performance.

Frequently Asked Questions

Q: Are the four serial interfaces independently configurable for protocol types?

A: Yes, the RS204 supports a combination of RS232, RS422, and RS485 on the same module, allowing for flexible connectivity with various field-level serial devices.

Q: Does the module provide galvanic isolation for the serial ports?

A: Yes, all four serial interfaces are galvanically isolated from the system electronics to mitigate common-mode noise and ground potential loops between connected devices.

Q: How are terminating resistors managed on the RS485 interface?

A: The module features integrated terminating resistors that can be toggled to connect or disconnect via software or local hardware configuration, simplifying field setup for RS485 bus topologies.

Field Installation Guidelines

  1. Wiring: Use shielded twisted-pair cables for RS422/RS485 connections. Connect the cable shield to a functional earth (FE) point to ensure effective noise rejection at high baud rates.
  2. Termination: Enable integrated terminating resistors only at the physical ends of the RS485 bus to prevent signal reflections and data errors.
  3. Isolation: Maintain physical separation between serial communication cables and high-power load lines to prevent electromagnetic interference (EMI).
  4. Connector Seating: Ensure the module is firmly seated in the backplane slot. Secure the terminal blocks properly to maintain low-impedance contact for high-speed transmission (up to 1.5 MBaud).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more