Configured for mechanical mounting and electrical interconnection in M200 system platforms, the Bachmann BS207 (BS207 Backplane Module) provides direct physical/electrical execution for module housing and bus distribution.

Suffix Breakdown & Model Matrix

The Bachmann BS207 is a fixed-slot backplane component. The model identifier "207" denotes the total count of available interface slots within the standard M200 form factor. No hardware suffixes exist for this model; it is provided as a standalone structural and communication distribution unit.

Hardware Specifications

Parameter Specification
Model BS207
Brand Bachmann
Origin Germany
Weight 0.6 kg
Dimensions 38.7 cm x 2.5 cm x 12.1 cm
Operating Temp -20 deg C to 60 deg C
Power Consumption Passive (Bus routing only)
Number of slots 7
Bus Support FASTBUS / M200 Internal Bus

Backplane bus communication velocity Licences

The Bachmann BS207 serves as the passive physical infrastructure required for high-speed deterministic communication across the M200 modular system. It facilitates the distribution of the backplane bus signals to all seven slots, maintaining signal integrity for communication velocities compliant with Bachmann processor specifications. The physical design supports the standardized bus expansion, ensuring that data transmission between the CPU and I/O modules adheres to latency requirements without additional signal conditioning. The interconnection architecture is designed to support modular system expansion while maintaining alignment with internal bus impedance standards.

Frequently Asked Questions

Q: Does the BS207 backplane include active switching components or microprocessors?

A: No, the BS207 is a passive interconnection device. It serves as a mechanical support and electrical bus distributor for modules installed in its seven slots.

Q: Is it possible to chain multiple BS207 backplanes together?

A: Yes, the backplane supports system expansion through standardized bus extension cables, provided the total system bus length does not exceed the communication specification limits of the host controller.

Field Installation Guidelines

  1. Mounting Stability: Secure the Bachmann BS207 backplane to a grounded DIN-rail or flat mounting plate within the control cabinet. Use the integrated mounting points to ensure the unit is mechanically rigid to withstand vibration profiles.
  2. Module Insertion: Ensure that all power is removed from the system before seating any I/O or processor modules into the seven available slots. Align the module guide rails carefully to prevent damage to the backplane connector pins.
  3. Grounding: Establish a clean electrical connection between the backplane chassis and the cabinet ground bus. This is critical for electromagnetic compatibility (EMC) and to provide a reference potential for the module shielding.
  4. Wiring Constraints: Ensure that the cabling for bus expansion does not run parallel to high-voltage AC power lines. Maintain a minimum separation distance as defined by standard industrial electrical codes to prevent induced noise on the backplane communication lines.
  5. Slot Integrity: Inspect the interface connectors for bent pins or debris before module installation. Ensure that unused slots are covered with appropriate dust-protection blanks if operating in high-particulate environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more