Skip to content

What are you looking for?


You may also like

Bachmann MX213 CPU ModuleBachmann MX213 CPU ModuleBachmann MX213 CPU Module
Bachmann MX213 CPU Module
Bachmann MX213 CPU Module
Bachmann MX213 CPU Module

Bachmann MX213 CPU Module


Only 10 left - Selling fast

PRODUCT SKU : MX213

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : Bachmann


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed process control in M1 automation platforms, the Bachmann MX213 (MX213 CPU Module) provides direct physical/electrical execution of logic processing and real-time machine task scheduling.

Hardware Specifications

Parameter Specification
Model MX213
Brand Bachmann
Origin Austria
Weight 0.35 kg (approx.)
Dimensions 102 mm x 12 mm x 130 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption 12 W (typical)
Processor AMD LX 266 MHz
Main Memory 256 MB
Retentive Memory 512 kB NVRAM

Profinet / EtherNet/IP Deterministic Networks

The MX213 integrates into the M1 rack backplane to support deterministic network connectivity for real-time control applications. The module utilizes backplane bus communication velocity to ensure synchronization between the CPU core and remote I/O modules, maintaining sub-millisecond task execution. The platform supports I/O density scaling, allowing for complex configurations that demand rapid data throughput across the system bus. Firmware flash compatibility is maintained to ensure the internal real-time operating system kernel remains synchronized with the latest platform drivers and hardware revision standards.

Frequently Asked Questions

Q: Does the MX213 support live hot-swapping while the controller is powered?

A: No, hot-swapping is not supported. The controller must be powered down before removing or installing the MX213 to prevent damage to the backplane bus interface and potential data corruption.

Q: How is the retention of program data managed during power loss?

A: The module features 512 kB of integrated NVRAM, which serves as retentive memory to maintain critical process variables and diagnostic states during power-off cycles.

Q: Can the mass storage be expanded beyond the internal 64 MB?

A: Yes, the module includes side-access slots for Compact Flash media and PC-Card storage (16/32/64 MB) to accommodate expanded data logging requirements.

Field Installation Guidelines

  1. Environmental Control: Ensure the module is installed in a ventilated cabinet to maintain operation within the 0 deg C to 60 deg C range. Avoid locations with high vibration or excessive dust.
  2. Backplane Seating: Verify the module is fully inserted into the backplane slots. Proper engagement of the bus connectors is mandatory for stable communication and system power distribution.
  3. Firmware Integrity: Ensure the firmware version of the MX213 is compatible with the installed M1 rack backplane and I/O modules before initial commissioning.
  4. Storage Media: When using Compact Flash or PC-Card media, ensure the side cover is securely fastened to prevent mechanical failure due to vibration or environmental contamination.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more