Configured for high-speed electrical network monitoring in M1 control platforms, the Bachmann GM260 (GM260 Grid Measurement Module) provides direct data acquisition of three-phase network variables.

Hardware Specifications

Parameter Specification
Model GM260
Brand Bachmann
Origin Austria
Dimensions Standard Bachmann module enclosure
Input Capacity 2 separate three-phase branches
Max Input Voltage 480 VAC (L-L) RMS
Harmonics Analysis Up to 40th harmonic

Profinet / EtherNet/IP Deterministic Networks

The GM260 module utilizes integrated processing to calculate True RMS grid variables online, ensuring the data provided to the deterministic network is cycle-time consistent. By computing harmonics up to the 40th order directly on the module, the load on the host CPU is minimized, facilitating efficient backplane bus communication velocity. The module integrates seamlessly with Bachmann SolutionCenter, allowing real-time access to active, apparent, and reactive power metrics. Firmware flash compatibility ensures that the grid calculation algorithms remain updated, providing accurate 4-quadrant energy counting within the M1 control environment.

Frequently Asked Questions

Q: Does the GM260 require external transducers for voltage measurement?

A: No. The module is designed to accept direct connections of input voltages up to 480 VAC (L-L) RMS, eliminating the need for intermediate voltage transducers in standard applications.

Q: How are energy values tracked within the module?

A: The module features 2 independent 4-quadrant (4Q) energy counters that are processed internally, ensuring precise energy monitoring without requiring external processing cycles.

Field Installation Guidelines

  1. Ensure all voltage and current connections are made in accordance with the local electrical safety standards and the module pinout diagram.
  2. Verify that the CT (Current Transformer) ratios are correctly configured in the SolutionCenter to ensure accurate current and power calculations.
  3. Utilize shielded cabling for all measurement inputs to prevent electromagnetic noise from interfering with the high-frequency harmonics sampling.
  4. Confirm that the common voltage monitoring point is correctly referenced to ground to prevent potential measurement offsets between the two three-phase branches.
  5. Perform an initial commissioning test using the SolutionCenter interface to verify that phase angles and RMS values align with secondary multimeter readings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more