Skip to content

What are you looking for?


You may also like

Allen Bradley 1734-IE4S Point I/O Safety Analog Input ModuleAllen Bradley 1734-IE4S Point I/O Safety Analog Input ModuleAllen Bradley 1734-IE4S Point I/O Safety Analog Input Module
Allen Bradley 1734-IE4S Point I/O Safety Analog Input Module
Allen Bradley 1734-IE4S Point I/O Safety Analog Input Module
Allen Bradley 1734-IE4S Point I/O Safety Analog Input Module

Allen Bradley 1734-IE4S Point I/O Safety Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1734-IE4S

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1734-IE4S is a Point I/O safety-rated analog input module designed for precise monitoring of analog signals in safety-critical applications. With four single-ended input channels, per-channel isolation, and compatibility with both thermocouples and RTDs, this module provides reliable integration into POINTBus systems. Its SIL/PL capability ensures compliance with safety standards, making it suitable for demanding industrial environments.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: Point I/O 1734

  • Part Number: 1734-IE4S

  • Weight: 0.19 lbs (0.09 kg)

  • Product Type: Safety Analog Input Module

  • Input Configuration: Single-ended

  • Input Channels: 4 channels

  • I/O Platform: POINTBus

  • Safety Rating: SIL/PL capable

  • Voltage Input Range: ±10 V

  • Current Input Range: 0–20 mA

  • Input Range (DC): 0–24 VDC

  • Supported Sensors: Thermocouples (TC) and RTDs (Pt, Nickel, Copper)

  • Channel Isolation: Per-channel isolation

  • Module Communication: POINTBus backplane

  • Typical Application: Safety analog sensing and monitoring

Application Scenarios

  • Safety-critical monitoring of analog signals in industrial automation

  • Integration with POINT I/O systems for distributed control architectures

  • Suitable for temperature sensing with RTDs and thermocouples

  • Ideal for current and voltage input monitoring in safety-rated systems

FAQ

Q: How many input channels does the 1734-IE4S provide?  A: It supports 4 single-ended input channels.

Q: What types of sensors are supported?  A: The module supports thermocouples and RTDs, including platinum, nickel, and copper types.

Q: Is the module SIL/PL rated?  A: Yes, it is SIL/PL capable, making it suitable for safety applications.

Comparison with Similar Models

  • 1734-IE4S: Safety-rated analog input, 4 channels, SIL/PL capable

  • 1734-IE2C: Standard analog input, 2 channels, non-safety rated

  • 1734-IR2: RTD input module, 2 channels, optimized for temperature sensing

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more