Product Overview

The 889D-F4AC-2 provides high-integrity electrical connectivity for industrial sensing and switching components. This DC Micro (M12) cordset features a straight female connector designed for rapid integration with Quick Disconnect (QD) sensors and actuators. It facilitates high-speed signal transmission and power delivery within automated production lines. We supply this product as 100% Brand New original stock, ensuring factory-sealed jacket integrity and optimal contact conductivity for critical control loops.

Technical Specifications

The 889D-F4AC-2 adheres to industry-standard M12 specifications for seamless cross-brand compatibility:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Connector Type M12 DC Micro (Straight Female)
Number of Pins 4-Pin
Cable Length 2 Meters (6.6 ft)
Current Rating 4 Amps
Voltage Rating 250V
Wire Size 22 AWG
Jacket Material Yellow PVC
Color Code Industry Standard Color Code A
Shielding Unshielded
Weight 0.20 lbs

Engineering Advantages

  • Optimized Signal Integrity: The 22 AWG conductors minimize voltage drop over the 2-meter span, ensuring that sensors receive stable power and return accurate logic signals to the PLC.

  • Standardized Color Coding: Utilization of "Color Code A" simplifies field wiring and troubleshooting. Maintenance teams identify wire functions instantly, reducing the risk of wiring errors during installation.

  • High-Visibility Jacket: The yellow PVC jacket enhances safety in crowded cable trays and dark machine bays. This high-visibility color allows for rapid visual inspections of cable routing and quick identification of DC Micro power circuits.

  • Robust Connector Overmold: The straight female M12 connector features a heavy-duty overmold that protects the internal pin terminations from mechanical strain and vibration. This construction prevents intermittent signal loss in high-vibration environments.

  • Flexible PVC Construction: The PVC jacket material provides excellent flexibility for routing through tight conduits or cable tracks while offering fundamental resistance to common industrial chemicals and oils.

FAQs

Q: Can I use the 889D-F4AC-2 with AC-powered sensors?

A: No. This cordset features the DC Micro (M12) keying system. While the insulation handles up to 250V, the physical keying prevents connection to AC Micro (1/2"-20) devices to ensure system safety and prevent cross-voltage hardware damage.

Q: Is this cable suitable for use in high-noise electromagnetic environments?

A: This specific model is unshielded. For applications situated near high-power VFDs or heavy motors where EMI is prevalent, consider a shielded variant (889DS) to prevent signal interference.

Q: What is the benefit of the Quick Disconnect (QD) design over hard-wiring?

A: The QD connector allows for "plug-and-play" sensor replacement. When a sensor fails, maintenance staff simply unscrew the M12 connector and swap the device without opening junction boxes or re-stripping wires, significantly reducing MTTR (Mean Time To Repair).

Q: Does the 2-meter length affect the current capacity?

A: The cordset maintains its 4 Amp rating throughout the 2-meter length. The 22 AWG copper thickness provides sufficient cross-sectional area to handle the full rated load without excessive thermal buildup.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more