Product Details

Configured for contact surface protection in industrial electrical assemblies, the Allen-Bradley 80158-357-51-R (80158-357-51-R Anti-Corrosion Grease) provides direct physical execution of oxidation prevention and environmental sealing for conductive interfaces.

Hardware Specifications

Parameter Specification
Model 80158-357-51-R
Brand Allen-Bradley
Origin USA
Weight 1.36 kg
Material Type Nyogel Lubricant

Profinet / EtherNet/IP Deterministic Networks

The 80158-357-51-R functions as a specialized chemical barrier designed to maintain signal integrity at electrical connection points. By preventing the formation of insulating oxide layers on metallic contacts, this lubricant ensures that data communication across Profinet and EtherNet/IP deterministic networks remains free of intermittent connection faults. While the grease itself is a passive material, its application is necessary in high-density I/O installations to mitigate the risk of corrosion-induced resistance fluctuations, which can degrade the communication stability of modular PLC backplane bus segments and sensitive instrumentation interfaces.

Frequently Asked Questions

Q: Is this lubricant conductive?

A: No. Nyogel is a dielectric, synthetic hydrocarbon grease. It is designed to seal electrical contacts from moisture and air to prevent corrosion without creating electrical bridges or short circuits between adjacent pins.

Q: Can this grease be used on high-voltage power terminals?

A: Yes. Its dielectric properties make it suitable for preventing oxidation on various power and signal terminations. Ensure the grease is applied sparingly to cover the contact surface without contaminating surrounding insulating materials.

Field Installation Guidelines

  1. Ensure the electrical contact surfaces are clean and free of existing contaminants, debris, or old lubricant before application.
  2. Apply a thin, uniform layer of the grease to the metal contact areas using a clean applicator or lint-free cloth.
  3. For multi-pin connectors, ensure the grease does not bridge across adjacent pins to avoid potential impedance issues in high-frequency signal lines.
  4. Re-mate the connectors to spread the lubricant evenly across the contact interface; verify that the connection is fully seated to ensure the seal is effective.
  5. Wipe away any excess grease that has been displaced during the mating process to prevent the accumulation of airborne dust or conductive debris.
  6. Periodic re-application may be required in harsh industrial environments; follow site-specific maintenance cycles for connector inspection and lubrication.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more