PRODUCT SKU : 1784-KTXD

PRODUCT TYPE : Communication Interface Card

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1784-KTXD functions as a high-speed communication interface card that enables direct connectivity between an industrial PC and Allen-Bradley PLC networks. This dual-channel card supports both Data Highway Plus (DH+) and DH-485 protocols, acting as a powerful remote scanner and diagnostic tool. It allows personal computers to upload/download ladder logic, monitor real-time process data, and interface with HMI/SCADA software. We supply this unit as 100% Brand New and factory-original, ensuring the hardware integrity required to maintain aging legacy systems that rely on the ISA bus architecture.

Technical Specifications

The 1784-KTXD utilizes a specialized onboard processor to handle network polling and data framing, offloading the communication burden from the host computer's CPU.

Feature Specification
Interface Type Dual-Channel Communication Card
Bus Architecture ISA (Half-Size Slot)
Network Protocols Data Highway Plus (DH+) and DH-485
Operation Mode Remote Scanner / Programming Interface
Current Consumption 600 mA @ 5 VDC
Isolation Standard Industrial Grade Network Isolation
Weight 0.31 lbs (0.14 kg)

Engineering Advantages

  • Simultaneous Multi-Protocol Support: The 1784-KTXD manages two separate communication channels. This allows an engineer to monitor a DH+ network on one port while simultaneously troubleshooting a DH-485 link on the second, eliminating the need for multiple interface cards.

  • Deterministic Data Throughput: The onboard intelligence manages the specific timing requirements of the DH+ token-passing protocol. This prevents data collisions and ensures that your HMI receives process updates with the precision required for high-speed industrial control.

  • ISA Legacy Preservation: This card provides a direct solution for maintaining older industrial workstations. By utilizing 100% Brand New stock, you avoid the common failures of used ISA boards, such as oxidized edge connectors or degraded capacitors, which cause intermittent communication drops.

  • Compact Half-Size Form Factor: The half-size ISA design fits into a wider variety of industrial PC chassis, including compact or shallow enclosures. This solves the physical constraints often encountered when retrofitting or repairing legacy machine-side controllers.

FAQs

  • Does the 1784-KTXD require a specific driver version?

    Yes. You must use the RSLinx Classic drivers that support the KTXD hardware. Ensure your operating system remains compatible with ISA-bus legacy drivers, as modern 64-bit Windows environments typically do not support this hardware directly.

  • Can I use this card to program SLC 500 and PLC-5 processors?

    Absolutely. The 1784-KTXD acts as the primary programming bridge for the PLC-5 (via DH+) and the SLC 500 family (via DH-485), providing full access to ladder logic and data tables.

  • What should I check if the computer fails to recognize the card?

    Verify the DIP switch settings on the board for the Base Memory Address and Interrupt (IRQ). ISA cards require manual resource allocation; ensure these settings do not conflict with other hardware in your PC's BIOS or Device Manager.

  • Is this a refurbished or repaired board?

    No. This unit is 100% Brand New. Unlike many surplus "KTXD" cards that show signs of previous installation or repair, our stock remains in pristine, original condition to guarantee maximum reliability in the field.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more