Skip to content

What are you looking for?


You may also like

1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module
1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module
1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module
1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module

1492-IFM40F-F24D-2 | Allen Bradley | ControlLogix 40-Point Isolated Fusible Interface Module


Only 10 left - Selling fast

PRODUCT SKU : 1492-IFM40F-F24D-2

PRODUCT TYPE : Interface Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1792-IFM40F-F24D-2 serves as a high-density, isolated fusible interface module (IFM) specifically engineered for the ControlLogix platform. This module streamlines the connection between PLC I/O cards and field devices by replacing traditional point-to-point wiring with a pre-wired cable interface. It provides 40 points of isolated circuit protection, utilizing $5 \times 20\text{mm}$ fuse clips to safeguard individual channels against overcurrent conditions. This IFM acts as a critical circuit protection layer, ensuring that field-side electrical faults do not damage expensive controller hardware.

Technical Specifications

Feature Detailed Specification
Manufacturer Allen Bradley / Rockwell Automation
Part Number 1492-IFM40F-F24D-2
Product Type Isolated Fusible Interface Module (IFM)
Compatible Series ControlLogix / Digital I/O
Point Count 40-Point
Fuse Type $5 \times 20\text{mm}$ Fuse Clips
Voltage Indication 24V AC/DC Blown Fuse Indicators
Wiring Configuration Extra Terminals for Output Circuits
Category Terminal Block/Strip Wiring Device
Weight 0.85 lbs (0.39 kg)
Condition 100% Brand New Original

Engineering Advantages

  • Accelerated System Deployment: The 1492-IFM40F-F24D-2 utilizes standard pre-wired cables to connect directly to 40-point ControlLogix I/O modules. This architecture eliminates manual wire stripping and labeling for 40 individual points, reducing cabinet assembly time by up to 75% while simultaneously removing the risk of cross-wiring errors.

  • Granular Circuit Protection: Integrated $5 \times 20\text{mm}$ fuse clips provide isolated protection for every channel. This isolation ensures that an electrical short on a single field actuator only blows its respective fuse, leaving the remaining 39 channels fully operational and preventing a total system shutdown.

  • Instant Visual Diagnostics: Built-in 24V AC/DC blown fuse indicators illuminate immediately upon fuse failure. This feature allows maintenance personnel to identify the exact failed circuit at a glance without using a multimeter, significantly lowering the Mean Time to Repair (MTTR) in complex automation cells.

  • High-Density Cabinet Optimization: By consolidating 40 points of fusing and termination into a single compact module, the 1492-IFM40F-F24D-2 saves significant DIN rail space compared to individual fuse blocks. This allows engineers to design smaller enclosures or add more I/O density within existing footprints.

  • Enhanced Output Flexibility: The module includes extra terminals specifically for output configurations. These additional connection points simplify the distribution of common power or ground signals to field devices, eliminating the need for external jumper bars or messy "daisy-chain" wiring.

FAQs

  • Is the 1492-IFM40F-F24D-2 supplied as Brand New?

    Yes. We supply this module as 100% Brand New in original factory packaging. Each unit remains in pristine condition with all fuse clips and indicators factory-tested for immediate deployment.

  • Does this module include the $5 \times 20\text{mm}$ fuses?

    Typically, IFM modules ship without the actual fuses to allow engineers to specify the exact amperage (e.g., 500mA, 1A, or 2A) required for their specific field devices. Ensure you install properly rated $5 \times 20\text{mm}$ glass or ceramic fuses before commissioning.

  • Can I use this module for both AC and DC signals?

    Yes. The 24V blown fuse indicators and the internal circuitry support both 24V AC and 24V DC signal levels. Always verify that your field voltage matches the 24V rating of the onboard LED indicators to ensure proper diagnostic functionality.

  • Which ControlLogix cables do I need for this module?

    This module generally pairs with 1492-CABLE# series pre-wired cables designed for 40-point modules (such as the 1756-OB32 or 1756-IB32). Select the cable length (0.5m to 5.0m) that best fits your cabinet layout.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more