Skip to content

What are you looking for?


You may also like

1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable
1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable
1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable
1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable

1492-ACABLE025UD | Allen-Bradley 1756 ControlLogix 2.5m Analog Interface Cable


Only 10 left - Selling fast

PRODUCT SKU : 1492-ACABLE025UD

PRODUCT TYPE : Analog Interface Cable

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 1492-ACABLE025UD is a high-precision, pre-wired analog interface assembly engineered specifically for the Allen-Bradley Bulletin 1756 ControlLogix platform. This cable serves as a critical link between high-density analog I/O modules and remote interface modules (IFMs), streamlining the integration of sensitive process signals. By utilizing a pre-manufactured connection, engineers can eliminate manual wiring errors and ensure consistent impedance across all signal paths.

This specific assembly is optimized for low-voltage, high-accuracy signals, including those from RTDs and thermocouples. The 1492-ACABLE025UD (Part Number: 1492-ACABLE025UD) features specialized shielding to mitigate electromagnetic interference (EMI), which is vital for maintaining the integrity of analog data in electrically noisy industrial environments. At a length of 2.5 meters, it provides sufficient reach for standard cabinet routing while maintaining signal quality.

Technical Specifications

  • Brand: Allen-Bradley (Rockwell Automation)

  • Model Designation: 1492-ACABLE025UD

  • Application Focus: Analog I/O, RTD, and Thermocouple input modules

  • Platform Compatibility: Bulletin 1756 ControlLogix Systems

  • Physical Length: 2.5 Meters (Approx. 8.2 Feet)

  • Cable Architecture: Multi-conductor shielded analog grade

  • Connector Type: 1756-specific RTB interface to D-shell/Header

  • Signal Support: Analog Current (4-20mA), Voltage (0-10V), mV, and Resistance

  • Weight: 1.40 lbs (0.64 kg)

  • Environmental Rating: Standard industrial indoor use

Comparison: Analog vs. Digital Cables

Unlike standard digital cables in the 1492 series, the 1492-ACABLE025UD is built with twisted-pair architecture and enhanced grounding characteristics. While digital cables prioritize current capacity for switching, this analog variant is focused on noise rejection and minimizing thermal EMF, which is essential when connecting thermocouple modules where micro-volt precision is required.

Engineering FAQ

Why is the "UD" suffix significant for this 1492 cable?The "UD" designation typically indicates the specific wiring pinout and connector orientation required for certain analog I/O modules. Using the wrong cable suffix can result in transposed signal polarities or mismatched cold-junction compensation (CJC) data.

Is this cable suitable for high-vibration environments?Yes, the factory-molded connectors on the 1492-ACABLE025UD provide a more secure and vibration-resistant connection than individual ferrules in a standard screw-terminal block, reducing the risk of intermittent signal loss.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more