Skip to content

What are you looking for?


You may also like

Allen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O ModuleAllen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O ModuleAllen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O Module
Allen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O Module
Allen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O Module
Allen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O Module

Allen Bradley 1769-IF4XOF2 CompactLogix 6-Channel Analog Combination I/O Module


Only 10 left - Selling fast

PRODUCT SKU : 1769-IF4X0F2

PRODUCT TYPE : Analog I/O Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Overview

The 1769-IF4XOF2 (Part Number 1769-IF4XOF2) is a high-performance analog expansion component designed for the CompactLogix and MicroLogix 1500 controller families. This module provides a versatile solution for systems requiring limited analog density, consolidating four high-resolution inputs and two high-speed outputs within a single-slot footprint. By supporting both voltage and current signals, the 1769-IF4XOF2 (1769-IF4XOF2) eliminates the need for separate dedicated modules in smaller applications, significantly reducing hardware costs and cabinet space.

Engineered for precision, the input channels can be configured for either differential or single-ended operation, providing flexibility in sensor wiring and noise rejection. The output channels are designed for rapid response, making them suitable for controlling proportional valves, variable frequency drives (VFDs), and other actuators requiring real-time modulation.

Detailed Specifications

  • Module Function Analog Combination Input and Output

  • Input Channels 4 Points (Differential or Single-ended)

  • Output Channels 2 Points (Single-ended)

  • Signal Ranges (Voltage) 0 to 10V DC

  • Signal Ranges (Current) 0 to 20 mA or 4 to 20 mA

  • Backplane Current (5V DC) 120 mA

  • Backplane Current (24V DC) 160 mA

  • Analog-to-Digital Conversion Successive Approximation (14-bit resolution)

  • Input Impedance (Voltage) 1 Megaohm

  • Input Impedance (Current) 250 Ohms

  • Output Load Range (Voltage) > 1000 Ohms

  • Output Load Range (Current) 0 to 300 Ohms

  • Operating Temperature 0 to 60 °C (32 to 140 °F)

  • Mounting Configuration DIN Rail or Panel Mount

  • Enclosure Type Open-style (IP20)

  • Dimensions 118 mm x 35 mm x 87 mm (4.65 x 1.38 x 3.43 in)

Primary Applications

The 1769-IF4XOF2 (Part Number 1769-IF4XOF2) is effectively deployed in various process and discrete automation environments

  • Temperature and pressure monitoring via 4-20mA transducers.

  • PID loop control for heating elements and cooling fans.

  • Controlling VFD speed references via 0-10V DC signals.

  • Fluid level management in small-scale storage and mixing tanks.

Technical FAQ

Can I mix voltage and current signals on the same module?Yes, each channel on the 1769-IF4XOF2 (1769-IF4XOF2) is individually configurable via software, allowing you to run a 0-10V sensor on one input and a 4-20mA sensor on another simultaneously.

Does this module require an external power supply?While the logic is powered by the CompactLogix backplane, the analog circuitry requires 24V DC power, which is typically supplied through the backplane by a 1769-series power supply.

Is it possible to use this with a MicroLogix 1500 controller?Yes, the 1769-IF4XOF2 (Part Number 1769-IF4XOF2) is fully compatible with the MicroLogix 1500 LRP and LSP processors when used with the appropriate expansion cable or base.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more