The Yokogawa ST2*D, also cataloged as the ST2*D Digital Input/Output Module Card, operates as a dedicated hardware component for contact signal insulation and high-density discrete I/O interfacing within Yokogawa CENTUM-XL and u-XL DCS platforms. It isolates On-Off contact signals from push button switches and limit switches, outputting status signals directly to process controllers via 32 integrated channels.

Hardware Specifications

Parameter Specification
Model ST2*D
Brand Yokogawa
Origin Japan
Weight 0.65 kg
Dimensions 482.6 mm x 110 mm x 120.5 mm
Operating Temp 0 to 50 deg C
Power Consumption System backplane powered
Channel Count 32 channels
Card Density Up to 16 relay input/output cards
Storage Temp -30 to 85 deg C
Operating Humidity Max 75% non-condensing
System Compatibility Yokogawa CENTUM-XL, u-XL DCS

4-20 mA HART Loop Protocol and Galvanic Isolation

The ST2*D module incorporates channel-to-channel isolation architecture designed to suppress field-side switching noise and prevent ground potential differentials from damaging internal control bus lines. Galvanic isolation barriers maintain signal integrity across discrete input paths, isolating high-voltage contact spikes from sensitive system electronics. Integrated operational status LEDs provide physical verification of individual relay states during live industrial execution.

Frequently Asked Questions

Q: What physical indicators are available on the ST2D for channel status verification?

A: The ST2D features front-panel LED indicators that display real-time operational status for each relay contact input/output channel.

Q: How does the ST2*D achieve electrical isolation from field switches?

A: The module relies on internal signal insulation circuits that electrically separate On-Off contact inputs (such as limit switches and push buttons) from the internal system logic bus.

Q: Can the ST2D be mounted in standard 19-inch racks?

A: Yes, with a physical width of 482.6 mm, the ST2D module enclosure conforms to standard 19-inch rack mounting dimensions.

Field Installation Guidelines

  • ESD Protection: Wear a grounded ESD wrist strap prior to handling the module to protect internal components from electrostatic discharge.
  • Environmental Limits: Install the module inside an enclosure that maintains operating ambient temperatures between 0 and 50 deg C and relative humidity below 75% non-condensing.
  • Wiring Separation: Route field contact wiring separately from high-voltage AC power lines to minimize induced electromagnetic interference on signal lines.
  • Grounding: Ensure cabinet mounting frames and cable shielding are bonded to a dedicated low-impedance safety ground point.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more