The Yokogawa RM81*A, also cataloged as the RM81 Memory Card Module, operates as a dedicated hardware component for firmware storage and system parameter retention within CENTUM XL and MICRO XL platforms.

Hardware Specifications

Parameter Specification
Model RM81*A
Brand Yokogawa
Origin Japan
Weight 1.25 lbs (0.57 kg)
Dimensions Standard Rack Slot Module Form Factor
Operating Temp 0 to 50 deg C
Power Consumption Backplane logic rail power draw
Memory Type Solid-state retention card interface

Fieldbus Connectivity & Loop Data Storage

The RM81*A memory card module stores essential system parameter maps and execution blocks used to coordinate 4-20 mA HART loop protocol transactions across field instrumentation subnodes. By providing dedicated memory buffering directly on the system rack backplane, the unit maintains data access integrity across digital communication interfaces, preventing parameter loss during system power cycles or fieldbus network reconfigurations.

Frequently Asked Questions

Q: How is data integrity verified on the RM81*A memory module during system boot routines?

A: The host controller performs checksum validation upon power-up to verify memory block consistency before executing loaded control configurations.

Q: Can the RM81*A memory module be hot-swapped while the system rack is powered?

A: Card removal or insertion must be performed with the slot powered down or in an offline state to prevent backplane signal corruption and data write errors.

Field Installation Guidelines

Insert the RM81*A module vertically into the designated system rack card slot until the backplane connectors establish full contact. Secure the module using the top and bottom panel retention screws to ensure mechanical stability and proper frame grounding. Ensure the installation environment is free from conductive dust and that anti-static grounding precautions are observed during card handling and slot placement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more