Skip to content

What are you looking for?


You may also like

Yokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input ModuleYokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input ModuleYokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input Module
Yokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input Module
Yokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input Module
Yokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input Module

Yokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : NFDV161-P00

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa NFDV161-P00 serves as a high-density interface for large-scale industrial automation, specifically within the STARDOM and DCS ecosystems. This module consolidates 64 discrete digital signals into a single I/O slot, allowing the central controller to monitor vast arrays of field switches, sensors, and status contacts. By utilizing galvanic isolation across all channels, it prevents field-side electrical surges from reaching the system backplane. We supply this unit as 100% Brand New, ensuring factory-original specifications and long-term hardware stability for your control architecture.

Part Number Breakdown

The NFDV161 series utilizes a structured suffix system to define connection methods and signal logic:

Code Segment Specification Technical Definition
NFDV161 Base Model 64-Channel Isolated Digital Input Module
-P Connection Type Pressure-clamp terminal block interface
00 Configuration Standard hardware revision and signal threshold

Technical Specifications

The NFDV161-P00 delivers precision 24V DC signal detection with robust electrical separation.

  • Input Capacity: 64 isolated discrete channels

  • Rated Input Voltage: 24 V DC

  • Input Thresholds: ON: 20 to 26.4 V DC | OFF: ≤ 5.0 V DC

  • Input Current: 2.5 mA ± 20% (per channel at rated voltage)

  • Response Time: ≤ 8 ms (Status input)

  • Isolation (Input-to-System): 2 kV AC for 1 minute

  • Isolation (Between Commons): 500 V AC for 1 minute (per 16-channel group)

  • Current Consumption: 550 mA @ 5 V DC (System supply)

  • Wiring Interface: Pressure-clamp or MIL-connector cable options

  • Weight: Approx. 0.3 kg

  • Condition: 100% Brand New and Original

Engineering Advantages

The NFDV161-P00 addresses critical I/O density and signal integrity challenges in modern plants:

  • Extreme Cabinet Space Efficiency: This module processes 64 inputs in the footprint typically occupied by 16 or 32-channel units. This 4x density increase reduces the number of required I/O racks and minimizes the total cabinet footprint, significantly lowering hardware and enclosure costs.

  • Multi-Tier Electrical Protection: The module features 2 kV AC isolation between field inputs and the system bus, plus 500 V AC isolation between 16-channel common groups. This "staged" isolation prevents ground loops and ensures that a localized electrical fault does not propagate across all 64 channels.

  • Rapid Signal Processing: An 8 ms response time enables real-time monitoring of high-speed process states. For human-machine interfaces, the module utilizes a 20 ms minimum detection time to capture momentary push-button presses accurately, even during high-traffic CPU cycles.

  • Maintenance-Free Wiring: The pressure-clamp terminal option eliminates the risk of terminal loosening caused by industrial vibration. These connectors maintain constant tension on the field wiring, preventing high-resistance connections and intermittent signal loss over years of continuous operation.

FAQs

How does the NFDV161-P00 handle high-voltage spikes?

The module tolerates instantaneous allowable input voltages up to 30.0 V DC. Beyond this, the 2 kV AC galvanic isolation protects the central controller by physically decoupling the field wiring from the internal system logic.

What is the advantage of the 16-channel common groups?

The 64 channels are divided into four 16-channel groups, each with its own isolated common. This architecture allows you to mix different power sources or signal segments within the same module while preventing electrical cross-talk between the groups.

Can I use this module for high-frequency pulse counting?

While optimized for status monitoring, the module supports a maximum ON/OFF cycle of 25 Hz for push-button inputs. For applications requiring kilohertz-range counting, we recommend a dedicated high-speed counter module rather than a standard digital input.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more