Product Overview

The Yokogawa NFAR181-S00 functions as a high-performance 12-channel RTD (Resistance Temperature Detector) input module designed for the CENTUM VP Distributed Control System (DCS). This module captures precise temperature data from field-mounted RTD sensors, converting resistance variations into high-resolution digital values for the Field Control Station (FCS). It occupies a critical role in thermal monitoring across petrochemical, pharmaceutical, and power industries. We supply this unit as 100% Brand New and Original, manufactured in Japan, to ensure the highest thermal measurement integrity for your mission-critical processes.

Part Number Breakdown

The NFAR181-S00 follows Yokogawa’s modular coding system to specify hardware standards:

Suffix Code Technical Definition
NFAR181 RTD Input Module (12-channel, isolated)
-S Standard Type Hardware
0 Always 0 (Basic Configuration)
0 Always 0 (Basic Configuration)

Technical Specifications

The NFAR181-S00 delivers low-drift temperature acquisition within a compact, rack-mounted profile.

  • Number of Channels: 12 independent channels.

  • Input Type: RTD (Resistance Temperature Detector).

  • A/D Conversion: High-resolution digital processing.

  • Dimensions: 2.2 cm (W) x 12.4 cm (D) x 12.6 cm (H).

  • Weight: 0.1 kg.

  • Data Update Period: 10 ms (High-speed scanning).

  • Country of Origin: Japan.

  • Condition: Guaranteed 100% Brand New and Original.

Engineering Advantages

The NFAR181-S00 addresses specific thermal sensing challenges through advanced hardware engineering:

  • Precision Thermal Mapping: The 12-channel density allows for comprehensive temperature profiling within reactors or distillation columns. This high channel count maximizes the utility of a single I/O slot, reducing the overall hardware footprint in the control cabinet.

  • Three-Wire Compensation Support: The internal circuitry automatically compensates for lead-wire resistance. This ensures that the DCS measures the actual resistance of the RTD element rather than the cable length, maintaining accuracy even with long-distance field runs.

  • Effective Noise Rejection: Low-level resistance signals often pick up electromagnetic interference (EMI). The NFAR181-S00 incorporates differential input filtering to suppress common-mode noise, providing stable temperature readings in environments with high-power electrical equipment.

  • Galvanic System Isolation: The module isolates field-side wiring from the internal DCS backplane. This protection prevents ground loops and electrical transients from affecting the central processor, safeguarding the stability of the entire control network.

FAQs

  • What RTD types does the NFAR181-S00 support?

    The module typically supports Pt100, JPt100, and other standard industrial RTD types. You must configure the specific sensor type within the CENTUM VP engineering software to ensure correct linear conversion.

  • Can the NFAR181-S00 replace older RTD modules in a legacy system?

    The NFAR181-S00 serves as the current standard for CENTUM VP FIO subsystems. While it maintains a similar footprint to older series, you should verify the compatibility of your existing terminal boards and software revision before installation.

  • How does the module handle a broken sensor wire?

    The module includes a burnout detection function. If an RTD wire breaks or the sensor fails, the NFAR181-S00 immediately sends a "Bad" status signal to the DCS, allowing for rapid troubleshooting and preventing erroneous control actions.

  • Is this a brand new original Yokogawa part?

    Absolutely. We supply only 100% Brand New hardware. Every NFAR181-S00 arrives in its original Yokogawa Japan factory packaging with matching serial numbers and intact manufacturer seals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more