The Yokogawa NFAF135-S00 functions as a high-precision frequency acquisition interface for the ProSafe-RS safety instrumented system. This module captures and processes frequency signals from field devices such as turbine flowmeters, speed sensors, and pulse generators. We supply this unit as 100% Brand New and Original, ensuring absolute signal integrity and compliance with rigorous safety standards for critical process monitoring.

Technical Specifications

Feature Details
Number of Channels 8 isolated channels
Input Frequency Range 0.1 Hz to 10 kHz
Frequency Accuracy 0.1% of reading
Input Signal Types Contact ON/OFF, Voltage Pulse (rectangular)
Min. Pulse Width 40 $\mu$s
Data Refresh Cycle 10 ms
Withstanding Voltage 500 V AC (Channel-to-System / Channel-to-Channel)
Internal Power Consumption 300 mA (5 V DC) / 400 mA (24 V DC)
Weight 0.3 kg

Engineering Advantages

  • Superior Galvanic Isolation: The NFAF135-S00 provides 500 V AC isolation between individual channels and between the field inputs and the system bus. This architecture prevents ground loops and protects the internal safety logic from high-voltage transients common in industrial motor control centers.

  • Rapid Response Monitoring: A 10 ms data refresh cycle ensures the safety station reacts instantly to speed fluctuations or flow surges. This high-speed processing allows for the implementation of precise overspeed protection and emergency shutdown (ESD) triggers.

  • Flexible Input Signal Conditioning: The module accepts both dry contact and voltage pulse inputs. Internal selectable shunt (1000 $\Omega$) and pull-up (68 k$\Omega$) resistors allow engineers to interface directly with various sensor types without requiring external signal conditioning hardware.

  • Robust Noise Rejection: By utilizing a 40 $\mu$s minimum input pulse width filter, the hardware effectively ignores high-frequency electromagnetic interference (EMI). This ensures the PLC counts only legitimate process pulses, maintaining accuracy even in proximity to high-power variable frequency drives (VFDs).

FAQs

  • What type of field power supply does this module require?

    The NFAF135-S00 allows you to select between 12 V DC and 24 V DC for the field power supply. Ensure your configuration matches the voltage requirements of your connected transmitters to avoid signal clipping or hardware damage.

  • Can I use this module for high-speed turbine speed sensing?

    Yes. The 10 kHz input limit and 0.1% accuracy make it ideal for monitoring turbine rotation speeds. For safety-critical overspeed protection, we recommend utilizing the module within a redundant ProSafe-RS architecture.

  • Does the module support MIL-standard cabling?

    Yes. The module offers two connection options: pressure clamp terminals for direct field wiring and MIL connector cables for rapid, centralized marshalling cabinet integration.

  • How does the module handle signal loss?

    The ProSafe-RS system diagnostics monitor the NFAF135-S00 continuously. If a signal falls outside the 0.1 Hz to 10 kHz range or the field power supply fails, the module immediately flags a diagnostic error to the safety controller for programmed fail-safe action.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more