Skip to content

What are you looking for?


You may also like

Yokogawa IP91*A Communication ModuleYokogawa IP91*A Communication ModuleYokogawa IP91*A Communication Module
Yokogawa IP91*A Communication Module
Yokogawa IP91*A Communication Module
Yokogawa IP91*A Communication Module

Yokogawa IP91*A Communication Module


Only 10 left - Selling fast

PRODUCT SKU : IP91*A

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa IP91*A, also cataloged as the IP91 Communication Module, operates as a dedicated hardware component for multi-protocol serial communication and data packet translation within Yokogawa DCS and SCADA networks.

Suffix Breakdown & Model Matrix

Code Element Specification / Description
IP91 Base model designation for industrial serial communication module
*A Style code Revision A specifying terminal pin layout and physical enclosure revision

Hardware Specifications

Parameter Specification
Model IP91*A
Brand Yokogawa
Origin Japan
Weight 0.15 kg
Dimensions Compact panel/slot mount module format
Operating Temp -10 deg C to 60 deg C
Power Consumption 12-24 VDC continuous operating supply
Module Type Communication Module
Supported Protocols Modbus RTU, ASCII, Binary
Serial Interface RS-232C / RS-485 configurable communication lines
System Integration Yokogawa DCS, SCADA, and field instrument networks

Channel-to-Channel Isolation and Multi-Protocol Serial Conversion

The IP91*A module converts raw serial field communications, including Modbus RTU, ASCII, and Binary protocols, into digitized backplane data streams for control system processing. Built-in channel-to-channel galvanic isolation shields internal processing circuits from ground loops and common-mode noise across RS-232C/RS-485 field loops. This isolation maintains signal integrity during high-baud-rate data transmission between field instruments and central DCS controllers.

Frequently Asked Questions

Q: How are communication protocol selections configured on the IP91*A module?

A: Protocol selection between Modbus RTU, ASCII, and Binary modes is established via internal DIP switch configuration settings and system engineering software initialization.

Q: Does the IP91*A module tolerate live insertion or removal during active host operation?

A: Module replacement should only be performed when the module power terminal is de-energized or when the connected communication bus is set to an inactive state to prevent frame corruption on the host network.

Q: What ground potential differences can the internal isolation barrier withstand?

A: The internal galvanic isolation barrier provides dielectric protection up to 1500 VAC between field serial lines and the internal logic power ground.

Field Installation Guidelines

  1. Mounting: Secure the module on a standard 35 mm DIN rail or designated chassis mounting slot. Verify that side retaining latches lock fully to prevent physical dislocation under mechanical vibration.
  2. Power Wiring: Connect a regulated 12-24 VDC auxiliary power supply to the designated power terminals. Verify correct voltage polarity before energizing the unit.
  3. Signal Cabling and Shielding: Route serial communication lines using shielded twisted-pair cables. Terminate cable shields to the cabinet functional earth (FE) bus at a single point to prevent ground loop currents.
  4. Line Termination: Ensure proper 120 ohm bus termination resistors are enabled at both physical ends of RS-485 communication loops to eliminate signal reflections over long cable runs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evaluating Industrial Automation: Architectural Benefits and Operational Challenges

Evaluating Industrial Automation: Architectural Benefits and Operational Challenges

Modern manufacturing relies heavily on advanced industrial automation to streamline production cycles and maintain precise process execution. Automated control systems, programmable logic controllers (PLCs), and distributed control systems (DCS) replace repetitive manual intervention on shop floors. Evaluating the balance between operational gains and capital investment remains essential for engineering leaders planning smart factory upgrades.

Read more
Strategic Emergency Shutdown Button Installation: Securing Industrial Gas Pipelines

Strategic Emergency Shutdown Button Installation: Securing Industrial Gas Pipelines

Emergency Shutdown (ESD) systems serve as the critical last line of defense in power plants and chemical facilities. Plant engineers frequently install manual ESD pushbuttons at boundary fence lines near gas pipeline entry points. Positioning safety devices far from main generation units ensures fast isolation and protects personnel during major gas releases.

Read more
Multi-Touch HMI Technology: Transforming Interaction in Industrial Automation

Multi-Touch HMI Technology: Transforming Interaction in Industrial Automation

Modern human-machine interfaces (HMIs) are evolving rapidly across factory floors worldwide. Traditional resistive touchscreens allowed operators to register only a single touch point at a time. Today, multi-touch HMI panels enable intuitive multi-finger gestures and concurrent multi-operator inputs in demanding industrial automation setups.

Read more