Yokogawa F3YD08-6A FA-M3 Transistor Output ModuleYokogawa F3YD08-6A FA-M3 Transistor Output ModuleYokogawa F3YD08-6A FA-M3 Transistor Output Module
Yokogawa F3YD08-6A FA-M3 Transistor Output Module
Yokogawa F3YD08-6A FA-M3 Transistor Output Module
Yokogawa F3YD08-6A FA-M3 Transistor Output Module

Yokogawa F3YD08-6A FA-M3 Transistor Output Module


Only 10 left - Selling fast

PRODUCT SKU : F3YD08-6A

PRODUCT TYPE : Transistor Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa F3YD08-6A functions as a high-integrity digital output interface for the FA-M3 multi-controller series. This module provides eight discrete transistor outputs to drive external solenoids, relays, and pilot lights in high-speed industrial environments. We supply this unit as 100% Brand New and Original, ensuring your control loops benefit from ultra-low leakage current and precision voltage switching.

Part Number Breakdown

Code Specification Description
F3YD08 Base Model 8-Point Transistor Output Module
-6 Output Rating Supports standard 12-24 VDC industrial loads
A Protection Logic Features integrated Active Clamp protection

Technical Specifications

Feature Details
Number of Outputs 8 Channels
Output Type Transistor
Rated Load Voltage 12 to 24 V DC
Max ON Voltage 0.5 V DC
Max OFF Leakage Current 0.1 mA
Internal Protection Active Clamp
Current Consumption 60 mA (5 V DC internal)
External Power Supply 12 to 24 V DC
Connection Method 10-point terminal block with M3.5 screws
Weight 130 g

Engineering Advantages

  • Inductive Load Protection: The F3YD08-6A incorporates an Active Clamp circuit. This protector suppresses back-EMF surges generated by inductive loads (like small motors or solenoid valves), preventing semiconductor failure and extending the lifespan of the module under high-frequency switching.

  • Superior Data Integrity: With a maximum OFF-time leakage current of just 0.1 mA, the module prevents "ghost" signals or unintended activation of sensitive high-impedance inputs. This high-isolation characteristic ensures absolute binary states in critical safety interlocks.

  • Mechanical Security: The module utilizes M3.5 screw terminals for field wiring. These provide significantly higher pull-out resistance than push-in terminals, making the F3YD08-6A ideal for high-vibration machinery found in automotive assembly or textile manufacturing.

  • Thermal Efficiency: The low 0.5 V DC maximum ON-voltage minimizes heat dissipation within the module during full-load operation. This efficiency maintains low cabinet temperatures, allowing for high-density rack configurations without the need for forced-air cooling.

FAQs

  • Does the F3YD08-6A support sinking or sourcing wiring?

    This module follows specific transistor output logic (typically sinking for "6A" variants). Always consult the wiring schematic for your specific FA-M3 rack to ensure the COM terminal matches your field power supply polarity.

  • Can I use this module to switch 110V AC loads?

    No. The F3YD08-6A operates strictly on 12-24 V DC. Attempting to switch AC voltages will permanently damage the transistor circuitry. Use an interposing relay if you need to control AC equipment.

  • What is the purpose of the HOLD/RESET current specification?

    The 10 mA HOLD/RESET current ensures the internal logic state remains stable even during minor voltage fluctuations. This ensures the output maintains its programmed state if the system undergoes a soft reset or low-power condition.

  • How do I replace a faulty unit without losing the field wiring?

    Since the module uses a 10-point terminal block, we recommend labeling all wires before removal. Ensure the power to the external 12-24V DC supply is OFF before disconnecting the M3.5 screws to avoid short circuits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding SCADA vs. HMI: A Technical Guide for Industrial Automation

Understanding SCADA vs. HMI: A Technical Guide for Industrial Automation

In the world of factory automation, professionals often use the terms HMI and SCADA interchangeably. However, these systems serve distinct roles within a control hierarchy. Understanding their unique functions is vital for designing efficient industrial automation architectures.

Read more
Microcontroller vs. PLC: Choosing the Right Controller for Industrial Automation

Microcontroller vs. PLC: Choosing the Right Controller for Industrial Automation

Engineers have long sought the perfect balance between flexibility and reliability when controlling complex systems. Today, two primary technologies dominate the landscape: the Microcontroller and the Programmable Logic Controller (PLC). While both serve as the "brain" of a system, they cater to vastly different environments. Understanding their core differences is essential for designing efficient control systems.

Read more
Essential DCS Commissioning Steps for Industrial Plant Success

Essential DCS Commissioning Steps for Industrial Plant Success

DCS commissioning is the vital bridge between construction and production. This phase validates that industrial automation infrastructure meets its functional design, ensuring safety and long-term reliability. By following rigorous protocols, engineers successfully transition from hardware installation to live process control.

Read more