PRODUCT SKU : CP471-01

PRODUCT TYPE : Processor Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The Yokogawa CP471-01 S2 Processor Module is engineered for CENTUM VP distributed control systems, delivering reliable execution of control logic and seamless I/O communication via the ESB bus. Supporting dual-redundant configurations, it ensures continuous operation and high availability. Equipped with Yokogawa’s proprietary system LSI, the module provides enhanced processing performance and operational stability in industrial environments.

Technical Specifications

  • Manufacturer Yokogawa Electric Corporation

  • Model CP471-01

  • Product Type Processor Module

  • System Compatibility CENTUM VP R6.01 or later

  • Processor Architecture Yokogawa proprietary system LSI

  • Memory 2 GB RAM, 512 MB Flash

  • Communication Interface ESB bus via EC401 coupler (style code S3 or later)

  • Redundancy Supports dual-redundant configuration

  • Mounting Field Control Unit (FCU) rack

  • Dimensions 170 mm × 105 mm × 32 mm

  • Weight 1.0 kg

  • Environmental Option ISA G3

  • Operating Temperature 0°C to 55°C

  • Storage Temperature -20°C to 70°C

Installation Notes

  • Install two CP471-01 modules in duplexed configuration for redundancy

  • Use EC401 bus coupler module (style code S3 or later)

  • Mount in designated FCU rack slots

  • Apply software patch for CENTUM VP R6.01 to R6.04 if required

  • Follow Yokogawa grounding and environmental guidelines

Ordering Options

  • -0: No explosion protection

  • -1: With ISA Standard G3 option

Application Scenarios

Used in CENTUM VP control systems for chemical plants, power generation, and petrochemical facilities. Ideal for applications requiring continuous I/O management and redundant control logic execution.

FAQ

Q1 What is the primary function of CP471-01?
A1 It executes control logic and manages I/O communication in CENTUM VP systems.

Q2 Can it be used in redundant setups?
A2 Yes, dual-redundant configuration is supported for continuous operation.

Q3 What communication bus does it use?
A3 It communicates via the ESB bus through an EC401 coupler (style code S3 or later).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more