Product Overview

The Yokogawa ANB10D-425/CU2N is a high-availability Duplicated Node Interface Unit (NIU) designed for the CENTUM VP Distributed Control System (DCS). This unit functions as a remote or local I/O subrack, housing up to 8 FIO (Field Input/Output) modules. The "D" designation indicates a Duplexed (Redundant) architecture, providing dual paths for power and communication. This specific model features G3-level corrosive resistance, making it the definitive choice for facilities exposed to aggressive atmospheric contaminants.

Condition: 100% Brand New and Original Factory Sealed.

Part Number Breakdown: ANB10D-425/CU2N

Yokogawa utilizes a comprehensive suffix and option code system to define the NIU's electrical and environmental properties:

  • ANB10D: Duplicated Node Interface Unit (for FIO).

  • -4: Dual-redundant 100-120 V AC Power Supply.

  • 2: 19-inch Rack-mount type with insulation bushing.

  • 5: With G3 Corrosive Resistance

  • /CU2N: Communication interface option specifying connector types and enhanced noise filtering.

Technical Specifications

The ANB10D-425 provides a stable and environmentally hardened electrical environment for critical I/O modules.

  • Number of I/O Slots: 8 slots (supports Analog, Digital, and Communication FIO modules)

  • Interface Bus: ESB Bus (Extended Serial Backplane)

  • Power Supply: 100-120 V AC, 50/60 Hz (Dual-redundant)

  • Mounting: Standard 19-inch rack-mount (with insulation bushing)

  • Environmental Protection: ISA Standard S71.04 Class G3

  • Current Consumption: Max 100 VA (at 100-120 V AC)

  • Redundancy: Supports dual PW481 power units and dual EC401 bus modules.

Engineering Advantages

  • G3-Rated Corrosive Resistance: The internal circuit boards of the ANB10D-425/CU2N are treated with a specialized conformal coating. This prevents silver and copper corrosion caused by aggressive gases in refineries and chemical plants, significantly extending the unit's lifespan in unconditioned environments.

  • Mission-Critical Availability: Engineered to eliminate single points of failure, this unit utilizes dual-redundant power supplies and ESB bus interfaces. This ensures that all 8 I/O modules remain online and communicating with the Field Control Unit (FCU) even if one power circuit or cable fails.

  • Ground Loop Protection: The "2" in the suffix indicates the inclusion of insulation bushings. This physical isolation prevents electrical noise from the cabinet frame from interfering with sensitive analog and digital signals, maintaining high signal-to-noise ratios.

  • Scalable I/O Distribution: This NIU allows for the physical distribution of I/O modules across the plant. By connecting several ANB10D units via YCB301 ESB bus cables, a single controller can manage widely dispersed field points while maintaining high-speed data synchronization.

  • Hot-Swappable Maintenance: All redundant components are hot-swappable. Maintenance teams can replace a faulty power supply or bus interface module while the system is live and the process is running, maximizing plant uptime.

FAQs

  • What is the difference between ANB10D and ANB11D?

    The ANB10D is for standard ESB Bus (local or near-distance), while the ANB11D is used for the Optical ESB Bus, allowing for much longer distances between the controller and the I/O node.

  • How do I connect the ANB10D-425 to the Field Control Unit?

    The NIU connects to the FCU (e.g., AFV30D) using ESB Bus Cables. For a redundant system, these cables must be used in pairs to maintain the duplicated communication path.

  • Does this unit include the I/O modules?

    No. The ANB10D-425/CU2N is the base chassis and power assembly. You must order specific I/O modules (e.g., AAI141, ADV151) separately based on your project's signal requirements.

  • Can I use this unit in a 220V AC environment?

    No. The suffix "-4" indicates a 100-120V AC rating. For 220-240V AC power environments, the ANB10D-2xx series is required.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more