Skip to content

What are you looking for?


You may also like

Yokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input ModuleYokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input ModuleYokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input Module
Yokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input Module
Yokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input Module
Yokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input Module

Yokogawa ADV151-P53/D5A00 CENTUM VP 32-Channel Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : ADV151-P10/B5S10

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADV151-P53/D5A00 serves as a ruggedized, high-density digital input solution for the CENTUM VP Integrated Production Control System. This 32-channel isolated module captures discrete 24 V DC signals from field switches, relay contacts, and sensors. Equipped with a KS Cable Interface Adapter and specialized environmental hardening, the ADV151-P53/D5A00 ensures continuous signal acquisition in the most demanding industrial atmospheres, including chemical processing and offshore environments.

Part Number Breakdown

The suffix and option codes define the specific hardware capabilities and environmental tolerances of this module:

  • ADV151: Digital Input Module (32-channel, 24 V DC, Isolated)

  • -P: Standard type signal processing

  • 5: Simplifies the interface by removing the external status display (No explosion protection)

  • 3: Adds ISA Standard G3 conformal coating and extends the temperature rating (-20 to 70°C)

  • /D5A00: Integrates the KS Cable Interface Adapter (Model: ATD5A-00) for high-density wiring

Technical Specifications

The ADV151-P53/D5A00 maintains high performance through the following engineered parameters:

  • Input Channels: 32 isolated digital inputs

  • Input Voltage: 24 V DC nominal

  • Isolation: Robust channel-to-system isolation

  • Environmental Protection: ISA Standard G3 (Corrosive gas resistance)

  • Operating Temperature: -20°C to 70°C

  • Connection Interface: ATD5A-00 KS Cable Interface Adapter

  • System Compatibility: CENTUM VP FIO Bus architecture

  • Weight: Approximately 0.3 kg

Engineering Advantages

  • Extreme Atmospheric Protection: The ISA Standard G3 option applies a specialized conformal coating to the internal circuitry. This barrier prevents corrosion from hydrogen sulfide ($H_{2}S$), chlorine, and other aggressive gases common in paper mills and refineries.

  • Wide Temperature Resilience: This module operates reliably across a broad thermal range from -20°C to 70°C. This eliminates the requirement for expensive climate-control equipment in non-ventilated field cabinets or remote outdoor installations.

  • Streamlined High-Density Wiring: The /D5A00 option replaces individual screw terminals with a KS Cable Interface Adapter. This enables a single-cable connection to remote terminal boards, significantly reducing the risk of wiring errors and accelerating the commissioning phase.

  • Superior Signal Integrity: Comprehensive isolation between field-side signals and the internal system backplane protects the controller from transients and electromagnetic interference (EMI). This architecture ensures that field-side ground loops never compromise system-wide data accuracy.

FAQs

Is the ADV151-P53/D5A00 supplied as a brand-new unit?

Yes. We supply the Yokogawa ADV151-P53/D5A00 exclusively as a 100% Brand New, original product. The module ships in its original factory-sealed packaging to ensure maximum operational life and authenticity.

What is the benefit of the /D5A00 adapter?

The /D5A00 adapter (Model ATD5A-00) allows the use of pre-fabricated KS cables. This solves the problem of labor-intensive manual wiring for 32 separate channels and provides a more secure, vibration-resistant connection point compared to standard terminals.

Can I install this module in a standard CENTUM VP rack?

Yes, this module fits into standard FIO node units. However, you must verify that your software configuration and the specific node unit support the P53 suffix features, particularly the extended temperature range and the KS cable interface.

Why does this model omit the status display?

The "5" suffix indicates a design without individual channel LEDs on the module faceplate. This configuration targets high-density cabinets where centralized software diagnostics replace visual hardware checks, thereby reducing internal heat generation and power consumption.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more