Only 10 left - Selling fast

PRODUCT SKU : AAI141-S50

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI141-S50 analog input module from Yokogawa is part of the Field I/O (FIO) platform, designed for accurate current signal acquisition in industrial automation systems. Unlike isolated modules, the AAI141-S50 is a non-isolated unit, optimized for applications where isolation is not required but precision and reliability remain critical. With 16 input channels, this module supports 4–20 mA DC signals and integrates seamlessly into dual-redundant configurations, ensuring system stability and dependable performance.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI141-S50

  • Type: Non-Isolated Analog Input Module

  • Channels: 16 analog input channels

  • Signal Range: 4–20 mA DC

  • Accuracy: ±0.1% of full scale

  • Resolution: 16-bit

  • Operating Temperature: -20°C to +70°C

  • Power Supply: 24 V DC

  • Redundancy: Dual-redundant configuration supported

  • Current Consumption:

    • 310 mA (5 V DC)

    • 450 mA (24 V DC)

  • Update Period: 10 ms

  • Step Response Time: 100 ms

  • Weight: 0.2 kg

Key Features

  • Non-Isolated Design: Simplifies installation where isolation is not required

  • High Resolution: 16-bit conversion for precise signal measurement

  • Compact and Lightweight: At 0.2 kg, easy to install and maintain

  • Dual-Redundancy Support: Ensures reliability in critical control systems

  • Energy Efficient: Low current consumption for stable operation

Application Scenarios

  • Oil and gas process monitoring

  • Chemical and pharmaceutical manufacturing

  • Power generation instrumentation

  • General industrial automation requiring non-isolated current input

FAQ

Q: How many channels does the AAI141-S50 provide?  A: It supports 16 non-isolated analog input channels.

Q: What type of signals can this module measure?  A: It is designed for 4–20 mA DC current signals.

Q: Is redundancy supported?  A: Yes, the module supports dual-redundant configurations for increased reliability.

Comparison with Similar Models

  • AAI143-S50: Isolated analog input module with HART support

  • AAI141-S50: Non-isolated version, optimized for simpler installations

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more