PRODUCT SKU : AAI135-S00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI135-S00 (Part Number: AAI135-S00) is a high-reliability current input interface designed for Yokogawa’s CENTUM VP and CS 3000 distributed control systems. This module is engineered to capture standard 4 to 20 mA signals from up to eight field instruments. Its primary technical advantage is the implementation of full galvanic isolation for each channel, which effectively eliminates ground loop interference and protects the system's central processors from field-side electrical transients.

As a standard type hardware component, the AAI135-S00 is optimized for high-precision data acquisition in non-hazardous environments. While some legacy listings may incorrectly cite high shipping weights, the module itself maintains a compact and lightweight industrial form factor of approximately 0.3 kg. It remains a critical component for plant engineers seeking to maintain or expand existing I/O nests where signal integrity is a top priority.

Detailed Technical Specifications

  • Number of Channels: 8 channels, individually isolated

  • Input Signal Type: 4 to 20 mA DC current

  • Conversion Accuracy: ±16 μA (approximately ±0.1% of span)

  • Input Resistance: 250 Ω (during active power-on state)

  • Data Refresh Cycle: 40 ms internal update period

  • Isolation Voltage: 1500 V AC dielectric strength for 1 minute (Input-to-System)

  • Temperature Drift: ±16 μA variation per 10°C change

  • Maximum Power Consumption: 360 mA at 5 V DC and 450 mA at 24 V DC

  • Operational Temperature: -20°C to 70°C for standard industrial use

  • Physical Dimensions: 10.7 cm x 13.0 cm x 3.3 cm

  • Unit Weight: 0.3 kg (exclusive of packaging)

Module Suffix and Configuration Analysis

  • AAI135: Base series designation for 8-channel isolated current input modules

  • -S: Standard performance and communication specification

  • 0: Non-explosion protected design for safe area installation

  • 0: Basic functional hardware type

Industrial Application Scenarios

  • Oil and Gas Refining: Monitoring critical pressure and temperature loops where isolation is required for safety.

  • Chemical Processing: Interfacing with high-precision sensors that must be protected from common-mode noise.

  • Power Generation: High-density data acquisition for boiler and turbine monitoring systems.

  • System Maintenance: Replacement of legacy I/O modules in existing CENTUM VP control racks.

Frequently Asked Questions

What is the benefit of the isolated architecture in this module?The AAI135-S00 uses transformer and optocoupler isolation. This ensures that if a transmitter fails or a surge occurs on one channel, it will not propagate to the other seven channels or the DCS backbone, maintaining overall system uptime.

Is this module compatible with HART-enabled devices?While the AAI135-S00 can read the 4-20 mA primary variable from a HART transmitter, it does not support digital HART communication pass-through. If you require diagnostic data access, the "H" suffix version (AAI135-H) is necessary.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more