Skip to content

What are you looking for?


You may also like

Woodward 9907-147 ProTech 203 Overspeed Protection SystemWoodward 9907-147 ProTech 203 Overspeed Protection SystemWoodward 9907-147 ProTech 203 Overspeed Protection System
Woodward 9907-147 ProTech 203 Overspeed Protection System
Woodward 9907-147 ProTech 203 Overspeed Protection System
Woodward 9907-147 ProTech 203 Overspeed Protection System

Woodward 9907-147 ProTech 203 Overspeed Protection System


Only 10 left - Selling fast

PRODUCT SKU : 9907-147

PRODUCT TYPE : Overspeed Protection Systems

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-integrity turbomachinery monitoring, the Woodward 9907-147 (9907-147 Overspeed Protection System) provides direct physical/electrical execution of speed-sensing and trip logic sequences within prime mover protection platforms.

Hardware Specifications

Parameter Specification
Model 9907-147
Brand Woodward
Origin Not specified
Weight < 17 lbs
Dimensions 482.6 x 310.4 x 142.7 mm
Operating Temp -25 to 60 deg C
Power Consumption Not specified
Input Voltage 24 VDC
Speed Range 100 Hz to 32 kHz
Trip Frequency 250 Hz to 25 kHz

Triple Modular Redundancy (TMR) 2oo3 Architecture

The 9907-147 utilizes a TMR 2oo3 architecture to ensure failsafe state execution during overspeed events. The system integrates three independent speed-sensing units that perform simultaneous frequency calculations based on magnetic pickup inputs. The internal voting logic requires at least two of the three units to detect an overspeed condition exceeding the programmed trip set point before the system transitions the output relays to the de-energized state. This redundancy prevents spurious trips caused by individual module drift or signal noise while maintaining high diagnostic coverage. Programming and operational state changes are governed by a physical key-locked interface, restricting access between MONITOR and PROGRAM modes to authorized personnel.

Frequently Asked Questions

Q: Is the system sensitive to electromagnetic interference (EMI)?

A: Yes, the 9907-147 is susceptible to EMI. It must be installed away from high-current or high-voltage devices. All signal cabling must utilize high-quality shielding, and shields should be grounded at the control cabinet entry point to maintain signal integrity for the magnetic pickup inputs.

Q: Can the trip set points for the three speed-sensing units be programmed independently?

A: While the interface allows for individual unit configuration, all three units must be programmed to identical trip set points to ensure the 2oo3 voting logic functions accurately. Mismatched set points will result in indeterminate relay behavior during speed transitions.

Field Installation Guidelines

  1. Mounting: Install the unit in a climate-controlled enclosure with adequate clearance for ventilation. Ensure the location is protected from direct sunlight, moisture, and excessive vibration, maintaining the ambient temperature within the -25 to 60 deg C range.
  2. Wiring: Use shielded twisted-pair conductors for all magnetic pickup connections. Ensure the cable length and impedance conform to the specific MPU characteristics to stay within the 100 Hz to 32 kHz sensing frequency range.
  3. Grounding: Connect the chassis to a dedicated earth ground bus to minimize noise susceptibility. Ensure that all redundant power supply inputs (if applicable) share a common reference point to prevent ground loops across the TMR modules.
  4. Validation: During commissioning, verify the 2oo3 voting logic by simulating trip signals on individual modules. Confirm that the relay outputs only transition to a trip state when a minimum of two units indicate an overspeed condition.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more