Skip to content

What are you looking for?


You may also like

Woodward 5501-469 CPU ModuleWoodward 5501-469 CPU ModuleWoodward 5501-469 CPU Module
Woodward 5501-469 CPU Module
Woodward 5501-469 CPU Module
Woodward 5501-469 CPU Module

Woodward 5501-469 CPU Module


Only 10 left - Selling fast

PRODUCT SKU : 5501-469

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for process control in NetCon platforms, the Woodward 5501-469 (5501-469 CPU Module) provides direct electrical execution of control logic and machine management for LM6000 turbine applications.

Hardware Specifications

Parameter Specification
Model 5501-469
Brand Woodward
Origin Not specified
Weight 2.00 lbs
Series NetCon CPU_040
Memory Configuration With LL Memory

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 5501-469-U utilizes a Motorola 68040-based architecture to process control algorithms in NetCon systems. The module is engineered with specific thermal heat sink dissipation profiles to ensure core temperature stability during high-speed logic execution. Control precision is maintained through active management of the actuator loop feedback response, interfacing with local I/O to perform real-time regulation. The module includes local logic memory (LL Memory) to support dedicated control tasks. Stable operation depends on maintaining proper chassis airflow to prevent thermal throttling of the processor core, as the module interfaces directly with the backplane for I/O communication and system status synchronization.

Frequently Asked Questions

Q: Is the 5501-469-U compatible with firmware versions designed for earlier NetCon CPU modules?

A: Compatibility depends on the specific firmware flash revision. Ensure the target backplane and supporting I/O modules support the 040 processor architecture before executing a firmware migration.

Q: Does this module support hot-swapping within the NetCon rack?

A: Hot-swapping is generally restricted in NetCon CPU modules due to the volatility of the backplane bus state. Power down the chassis before installing or removing the CPU to prevent potential damage to the backplane pins or data corruption on the control bus.

Field Installation Guidelines

  • Mounting: Carefully align the module with the NetCon rack guides. Ensure the backplane connector is fully engaged to prevent intermittent communication errors.
  • Grounding: Secure the module faceplate screws to the chassis to ensure a solid path for electrostatic discharge (ESD) protection.
  • Wiring: Verify all I/O connections to the NetCon rack are verified for continuity prior to initializing the CPU. Ensure that communication cables are routed away from high-current power lines to avoid induced noise.
  • Start-up: Upon initial power-up, monitor the diagnostic LEDs for processor health status. Verify that the system boot-up sequence completes without signaling processor bus faults.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more