PRODUCT SKU : SS823 3BSE038226R1

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for voting diode execution and power supply decoupling in System 800xA and High Integrity controller networks, the ABB SS823 3BSE038226R1 (SS823 Voter and Over Voltage Protection Module) provides direct physical/electrical execution. The module manages dual 24 VDC power input channels, providing load sharing and over-voltage clamping to prevent transient power fault propagation across downstream automation backplanes. Internal supervision relays actively track voltage integrity and fault states to drive system diagnostics.

Hardware Specifications

Parameter Specification
Model SS823 3BSE038226R1
Brand ABB
Origin Sweden
Weight 870 g (1.9 lbs)
Dimensions 116 mm x 145 mm x 132 mm (4.6 in x 5.8 in x 5.3 in)
Operating Temp 55 deg C maximum ambient
Power Consumption Heat dissipation 24 W at 20 A load (6 W at 5 A load)
Nominal Input Voltage 1 x 24 VDC
Maximum Input Voltage Limit 60 VDC
Rated Input Power 500 W
Rated Output Current 20 A (Maximum overload threshold: 35 A)
Output Voltage Drop 1.2 V lower than input voltage at maximum current
Over Voltage Protection Cut-off threshold less than 30 V
Diagnostics & Features Load sharing, Supervision relay, High Integrity support

Backplane Bus Communication Velocity and High Integrity Deterministic Scaling

The SS823 module integrates directly into High Integrity power distribution networks, ensuring continuous, surge-protected DC bus stabilization without introducing transmission delays to adjacent I/O communication buses. Firmware flash compatibility across system power controllers enables real-time voltage monitoring, allowing the supervisory relay to isolate power rail faults instantly. High-density component layout provides rapid thermal dissipation while maintaining deterministic power availability during peak load transients.

Frequently Asked Questions

Q: What is the primary function of the internal supervision relay on the SS823?

A: The supervision relay monitors internal diode health and power channel status, changing state to trigger system alarms if an input channel fails or falls out of tolerance.

Q: What is the maximum over-voltage limit supported by the SS823 before output clamping occurs?

A: The module limits output voltage spikes to less than 30 V to protect sensitive processing boards and I/O modules connected downstream.

Field Installation Guidelines

  1. Mount the module vertically on standard DIN rails inside the enclosure, maintaining a minimum clearance spacing of 15 mm horizontally and 30 mm vertically to allow natural thermal convection.
  2. Ensure input wiring matches 24 VDC polarity specifications and that supply circuits are de-energized before making terminal block connections.
  3. Torque all power terminal screws to manufacturer-specified mechanical limits (typically 0.5 to 0.8 Nm) to ensure low-resistance electrical contact under high current loads.
  4. Verify that supervisory relay signal cables are routed separately from high-voltage AC distribution conductors to minimize electromagnetic interference.
  5. Connect protective earth (PE) grounding terminals directly to the cabinet ground busbar using a short, thick copper strap.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Functional Safety Terminology in Industrial Automation

Mastering Functional Safety Terminology in Industrial Automation

In modern process control and factory automation, managing operational risk is a top engineering priority. High-speed machinery, high-pressure vessels, and continuous processes present constant hazards to personnel and equipment. Modern plant operations rely heavily on functional safety strategies to mitigate these risks. This guide breaks down the essential functional safety terminology that every control systems engineer should master.

Read more
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more