Skip to content

What are you looking for?


You may also like

Schneider TSXASR402 Analog Output Module for Modicon TSX MicroSchneider TSXASR402 Analog Output Module for Modicon TSX MicroSchneider TSXASR402 Analog Output Module for Modicon TSX Micro
Schneider TSXASR402 Analog Output Module for Modicon TSX Micro
Schneider TSXASR402 Analog Output Module for Modicon TSX Micro
Schneider TSXASR402 Analog Output Module for Modicon TSX Micro

Schneider TSXASR402 Analog Output Module for Modicon TSX Micro


Only 10 left - Selling fast

PRODUCT SKU : TSXASR402

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider TSXASR402 Analog Output Module is designed for the Modicon TSX Micro programmable logic controller (PLC) family. It provides reliable digital-to-analog conversion for process control and automation systems. With four independent output channels supporting both voltage and current modes, this module enables precise control of actuators, drives, and analog devices within industrial environments. Its robust design ensures stable performance under varying temperature and electrical conditions, making it suitable for demanding automation tasks.

Technical Specifications

  • Manufacturer Schneider Electric / Telemecanique

  • Model TSXASR402

  • Product Type Analog Output Module

  • Compatible Series Modicon TSX Micro PLCs

  • Number of Output Channels 4 isolated channels

  • Output Signal Types 0–10 V DC or 4–20 mA

  • Resolution 10 or 12 bits (depending on configuration)

  • Conversion Speed Milliseconds-level response time

  • Output Accuracy ±0.1% of full scale

  • Operating Temperature Range 0°C to 60°C

  • Storage Temperature Range -20°C to 85°C

  • Dimensions 130 mm × 100 mm × 60 mm

  • Weight 0.5 kg

  • Mounting DIN rail installation

  • Isolation Channel-to-bus isolation for enhanced noise immunity

Application Scenarios

  • Industrial automation systems requiring precise analog signal control

  • Process control applications such as temperature, pressure, and flow regulation

  • Motion control systems involving servo drives or analog actuators

  • Plant monitoring and feedback systems using Modicon TSX PLC architectures

FAQs

  • Q1: Is the TSXASR402 compatible with all Modicon TSX Micro CPUs?
    A1: Yes, it is compatible with all standard TSX Micro PLC CPUs supporting analog output modules.

  • Q2: Can this module output both voltage and current simultaneously?
    A2: Each channel can be configured individually, but not both signal types simultaneously on the same channel.

  • Q3: Does the module require external power?
    A3: It is powered directly from the PLC backplane and does not require an additional external power supply.

  • Q4: What kind of isolation does the TSXASR402 offer?
    A4: Each output channel is electrically isolated from the PLC bus to reduce interference and protect connected devices.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more