Skip to content

What are you looking for?


You may also like

Schneider Electric TSXAEY1600 Modicon Premium Analog Input ModuleSchneider Electric TSXAEY1600 Modicon Premium Analog Input ModuleSchneider Electric TSXAEY1600 Modicon Premium Analog Input Module
Schneider Electric TSXAEY1600 Modicon Premium Analog Input Module
Schneider Electric TSXAEY1600 Modicon Premium Analog Input Module
Schneider Electric TSXAEY1600 Modicon Premium Analog Input Module

Schneider Electric TSXAEY1600 Modicon Premium Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : TSXAEY1600

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric TSXAEY1600 processes high-level analog current and voltage signals within the Modicon Premium automation platform. This high-density 16-channel analog input module decodes standard process variables from field instruments, including pressure transmitters, temperature sensors, flow meters, and variable speed drives. By hosting multi-range software configurations per channel and providing high galvanic isolation, this module serves as the primary data acquisition bridge for chemical manufacturing plants, water treatment facilities, and complex machinery automation grids.

Technical Specifications

Parameter Technical Specification Value
Manufacturer Schneider Electric
Model TSXAEY1600
Range of Product Modicon Premium Automation platform
Product Type High-level analog input module
Condition 100% Brand New Original
Number of Channels 16 high-level inputs
Analogue Input Types (Voltage) +/- 10 V, 0...10 V, 0...5 V, 1...5 V
Analogue Input Types (Current) 0...20 mA, 4...20 mA
Analog-to-Digital Conversion 12 bits
Nominal Read Cycle Time 51 ms for all active channels
Fast Read Cycle Time 3 ms + (3 ms x number of channels used)
Voltage Measurement Error (25 °C) 0.1% of full scale (+/- 10 V, 0...10 V, 0...5 V, 1...5 V)
Voltage Measurement Error (0...60 °C) 0.13% of full scale (+/- 10 V, 0...10 V, 0...5 V, 1...5 V)
Current Measurement Error (25 °C) 0.16% of full scale (0...20 mA, 4...20 mA)
Current Measurement Error (0...60 °C) 0.32% of full scale (0...20 mA, 4...20 mA)
Channel Isolation Barriers

1000 Vrms between channels and internal bus


1000 Vrms between channels and station ground

Channel-to-Channel Topology Common point architecture (no common mode between channels)
Input Overvoltage Protection

-15...15 V at state 0 (250 kOhm)


-30...30 V at state 1 (250 kOhm)

Input Overcurrent Protection -30...30 mA at state 1 (250 kOhm)
Electrical Connection Interface 2 x SUB-D 25-pin high-density connectors
Current Consumption 270 mA at 5 V DC
Module Physical Format Standard single-width slot size
Product Net Weight 0.75 lb (0.34 kg)

Engineering Advantages

  • 16-Channel High-Density Integration for Compact Enclosures: Modern control panels demand massive instrumentation capacities within limited rack space, which often forces engineers to buy multiple low-density input cards. The TSXAEY1600 packs 16 high-level analog inputs into a single standard slot format. This tight spatial layout allows facilities to consolidate high-density telemetry wireways into a smaller chassis footprint, freeing up valuable rail space inside crowded control enclosures.

  • Dual-Speed Configurable Read Cycle Engine: Mixing slow, stable environmental variables like tank levels with ultra-fast variables like hydraulic pressure loops usually requires separate specialized hardware. The TSXAEY1600 solves this limitation with its flexible scanning engine. It offers a 51 ms nominal read cycle for standard process loops, alongside a configurable fast-scan mode operating at 3 ms + 3 ms per active channel. This feature allows operators to optimize scanning speeds based on the exact needs of the field instrumentation.

  • Universal Voltage/Current Signal Compatibility: Multi-zone industrial systems often feature a mix of 4-20 mA current loops and 0-10 V voltage transmitters, which typically complicates hardware inventory management. This module supports broad signal configuration natively. Software parameters adjust individual channels to accept 0-20 mA, 4-20 mA, +/-10 V, 0-10 V, 0-5 V, or 1-5 V signals, allowing a single spare card to support diverse field configurations across the plant floor.

  • 1000 Vrms Robust Overvoltage Surge Defense: Cross-talk, ground potential shifts, or lightning strikes in outdoor field cable trays can send high-voltage surges back to the main electrical room. The TSXAEY1600 includes heavy-duty galvanic protection, establishing a 1000 Vrms isolation barrier between the input lines, station ground, and the internal backplane bus. Additionally, internal clamping networks provide continuous input overvoltage protection up to +/-30 V and overcurrent shielding up to +/-30 mA, stopping destructive surges before they reach the main processor.

  • Secure Dual SUB-D 25 Connection Architecture: High-vibration environments like compressor skids or rolling mills can loosen traditional screw terminals, leading to intermittent signal drops. The TSXAEY1600 utilizes two secure SUB-D 25-pin connector interfaces on the front panel. These mechanical plugs lock directly into place, providing vibration-proof contact points for complex multi-conductor cables while speeding up terminal disconnects during routine maintenance shop checkups.

FAQs

  • Is this TSXAEY1600 analog input module a 100% brand new item?

    Yes. We supply this module strictly as a 100% brand new, original factory-sealed unit. It arrives inside its authentic original Schneider Electric corporate carton, complete with undamaged anti-static shielding bags, unmarred faceplate plastics, and matching factory serial number tracking labels.

  • Does this module feature fully isolated channel-to-channel paths?

    No. The TSXAEY1600 utilizes a high-density common point architecture where the 16 channels share an internal reference path, resulting in no common mode between channels. However, the module provides a full 1000 Vrms galvanic isolation barrier between the combined channel array, the internal backplane bus logic, and the station ground.

  • How does temperature affect the measurement accuracy of this module?

    At a standard reference temperature of 25°C, the module achieves an accurate voltage reading within 0.1% of full scale. When operating across the expanded industrial enclosure range from 0°C up to 60°C, the internal precision components limit thermal drift, keeping the total voltage measurement error under 0.13% of full scale.

  • Can I configure different signal types on adjacent channels simultaneously?

    Yes. The Modicon Premium configuration software allows you to assign independent input definitions to individual channels. For example, you can set Channel 0 to read a 4-20 mA current loop while configuring Channel 1 to monitor a 0-10 V voltage signal on the same card, providing excellent flexibility for mixed-instrumentation setups.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more