Skip to content

What are you looking for?


You may also like

Schneider Electric BMXART0814 Modicon X80 Isolated Analog Input ModuleSchneider Electric BMXART0814 Modicon X80 Isolated Analog Input ModuleSchneider Electric BMXART0814 Modicon X80 Isolated Analog Input Module
Schneider Electric BMXART0814 Modicon X80 Isolated Analog Input Module
Schneider Electric BMXART0814 Modicon X80 Isolated Analog Input Module
Schneider Electric BMXART0814 Modicon X80 Isolated Analog Input Module

Schneider Electric BMXART0814 Modicon X80 Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : BMXART0814

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric BMXART0814 acts as a high-density, fully isolated analog input module within the Modicon X80 automation platform. This hardware intercepts millivolt and microvolt signals directly from high-precision thermocouples and resistance temperature detectors (RTDs) deployed on the plant floor. It translates these raw thermal voltage changes into highly accurate digital data for Modicon M340 and M580 programmable automation controllers. We guarantee this product arrives in 100% brand new, original factory-sealed condition.

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Product Line Modicon X80 Platform
Part Number / Model # BMXART0814 / BMX-ART-0814
Module Type Isolated Analog Input Module
Number of Inputs 8 Analog Channels
Channel Isolation Fully Isolated Input-to-Channel and Input-to-Bus
Input Impedance 10 MOhm
Analog to Digital Conversion Sigma-Delta 16-bits
Analogue Input Resolution 15 bits + sign
Common Mode Rejection 120 dB at 50/60 Hz
Differential Mode Rejection 60 dB at 50/60 Hz
Onboard Signal Filtering First-order digital filtering
Nominal Read Cycle Time 200 ms with thermocouple / 400 ms with temperature probe
Permitted Input Overload $\pm7.5\text{ V}$ across all native operational scale windows ($\pm1.28\text{ V}$$\pm160\text{ mV}$$\pm320\text{ mV}$$\pm40\text{ mV}$$\pm640\text{ mV}$$\pm80\text{ mV}$)
Electrical Connection 2 connectors x 40 ways
Current Consumption 150 mA at 3.3 V DC
Ingress / Mechanical Protection IP20 Rating
Vibration / Shock Resistance 3 gn continuous / 30 gn peak
Environmental Harshness Class 3C3 and 3C4 conforming to EN/IEC 60721-3-3
Ambient Operating Temperature 32 to 140 °F (0 to 60 °C)
Compliance Standards EN/IEC 61131-2, EN/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201

Engineering Advantages

  • High-Attenuation Industrial Noise Immunity: This card delivers a massive 120 dB common-mode rejection ratio and 60 dB differential-mode rejection at 50/60 Hz. This specialized filtering isolates the delicate microvolt-level sensor signals from heavy AC grid hum, magnetic cross-talk, and electrical motor noise present in harsh factory settings.

  • Severe Corrosive Environment Survival: The module meets 3C3 and 3C4 harshness standards under EN/IEC 60721-3-3 definitions. This advanced chemical hardening protects the internal copper traces and surface-mount components from catastrophic oxidation in high-sulfur or high-chlorine settings like oil refineries, chemical processing plants, and wastewater facilities.

  • High-Precision Sigma-Delta Digitization: An integrated 16-bit Sigma-Delta analog-to-digital converter paired with a first-order digital filter tracks rapid process variations smoothly. The hardware achieves an impressive 15-bit plus sign resolution, allowing process engineers to monitor precise fraction-of-a-degree temperature adjustments inside high-temperature kilns or blast furnaces.

  • Overload Fault Tolerance Framework: The module withstands sudden voltage surges up to $\pm7.5\text{V}$ across all primary input spans. This robust hardware cushion prevents component burnout when short circuits or ground faults accidentally drop raw field power into the sensitive thermocouple instrumentation lines.

FAQs

  • Does this BMXART0814 input module ship inside an original factory box?

    Yes. We supply this module exclusively as a 100% brand new, authentic factory-original unit. It arrives inside its genuine sealed Schneider Electric box containing the untouched anti-static inner wrap, unblemished manufacturing tracking codes, and official installation guidelines.

  • Does this module support both thermocouples and RTD temperature probes?

    Yes. The universal hardware profile accommodates both sensor families. The internal processor automatically adjusts the scanning speed to match the chosen sensor profile, executing a fast 200 ms read cycle for standard thermocouples and a stable 400 ms cycle for high-accuracy temperature probes.

  • What type of wiring arm or block do I need to attach to the two 40-way ports?

    The module utilizes two high-density 40-way connector slots. To maximize connection reliability and simplify layout design, you must select either a matching 40-way terminal block kit or interface the module directly with a Telefast pre-wired cable and terminal system.

  • Can I replace an active module on the backplane rack without cutting system power?

    Yes, provided you install it inside a Modicon X80 backplane controlled by an M580 or M340 processor that supports Hot Swapping (RIUP - Removal and Insertion Under Power). The module's internal power bus components protect the system from backplane arcing during active field replacement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Microcontroller vs. PLC: Choosing the Right Control System Architecture

Microcontroller vs. PLC: Choosing the Right Control System Architecture

This technical guide clarifies the distinctions between microcontrollers and Programmable Logic Controllers (PLCs), detailing their specifications, structural differences, and industrial positioning.

Read more
Understanding FIFO and LIFO Advanced Data Buffer Sequences in PLC Programming

Understanding FIFO and LIFO Advanced Data Buffer Sequences in PLC Programming

This technical brief explains the mechanical operation, instruction block parameters, and deployment strategies for these stack sequences within modern industrial control systems.

Read more
Engineering the Future: PLC Programmer Salary and Career Trajectory

Engineering the Future: PLC Programmer Salary and Career Trajectory

Maximize your earning potential in industrial automation. This technical guide analyzes PLC programmer salary structures across system integrators, OEMs, and top vendors, mapping out the definitive career path to transition from traditional ladder logic into high-paying IT/OT convergence and Industry 4.0 architecture.

Read more