Skip to content

What are you looking for?


You may also like

Schneider Electric 170AAI14000 Modicon Momentum Analogue Input Base ModuleSchneider Electric 170AAI14000 Modicon Momentum Analogue Input Base ModuleSchneider Electric 170AAI14000 Modicon Momentum Analogue Input Base Module
Schneider Electric 170AAI14000 Modicon Momentum Analogue Input Base Module
Schneider Electric 170AAI14000 Modicon Momentum Analogue Input Base Module
Schneider Electric 170AAI14000 Modicon Momentum Analogue Input Base Module

Schneider Electric 170AAI14000 Modicon Momentum Analogue Input Base Module


Only 10 left - Selling fast

PRODUCT SKU : 170AAI14000

PRODUCT TYPE : Analogue Input Base Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric 170AAI14000 acts as a high-density analogue input base module within the distributed Modicon Momentum automation platform. This foundation architecture houses 16 single-ended channels to interface field instruments—such as pressure transducers, flow meters, temperature transmitters, and level sensors—with a centralized programmable logic controller. The base converts raw voltage and current signals into high-resolution digital data packets, enabling real-time monitoring and deterministic loop control across large-scale process plants. We guarantee this analogue input base arrives in 100% brand new, original factory-sealed condition.

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Product Line Modicon Momentum Automation Platform
Part Number 170AAI14000
Product Type Analogue Input Base Module
Number of Channels 16 Single-Ended Inputs
Input Configurations 4...20 mA, $\pm 10\text{ V}$$\pm 5\text{ V}$
Analogue Resolution

12 bits (4...20 mA)


12 bits + sign ($\pm 10\text{ V}$, $\pm 5\text{ V}$)

Data Format Full 16 bits signed
Input Hardware Filter Low pass input filter at 10 kHz
Absolute Accuracy Error

$\pm 0.15\%$ of full scale @ 77°F (25°C) ($\pm 10\text{V}$, $\pm 5\text{V}$)


$\pm 0.25\%$ of full scale @ 77°F (25°C) (4...20 mA)


$\pm 0.45\%$ of full scale @ 140°F (60°C) (4...20 mA)

Channel Update Time 25 ms
Input Impedance $< 0.25\text{ Ohm}$ (Current) / $> 2200\text{ kOhm}$ (Voltage)
Isolation Strength 1780 V AC between channels and ground
Permissible Common Mode 100 V DC / 250 V AC (47...63 Hz) between channels to ground
Current Consumption Typical 305 mA at 24 V DC
Power Dissipation 5.55 W
Local Diagnostics 16 green LEDs for individual channel status tracking
Dimensions (H x W x D) 4.9 in (125 mm) x 5.6 in (141.5 mm) x 1.9 in (47.5 mm)
Module Weight 0.474 lbs (0.215 kg)

Engineering Advantages

  • High-Density Data Capture in Tight Footprints: This hardware integrates 16 distinct analogue sensor interfaces within a compact physical shell measuring less than 2 inches deep. This ultra-slim profile allows installation inside shallow junction boxes or directly onto machinery frames, bypassing the need for oversized, expensive control enclosures.

  • Aggressive Noise Suppression Over Long Cable Runs: An integrated 10 kHz low-pass hardware filter suppresses high-frequency electromagnetic interference (EMI) and cross-talk caused by neighboring variable frequency drives or high-voltage motor lines. This ensures stable, uncorrupted data conversion even when routing unshielded instrumentation cables across busy plant floors.

  • Robust High-Voltage Surge Protection: The internal circuit path features 1780 V AC isolation between the input channels and ground, alongside heavy-duty common-mode voltage limits (up to 250 V AC). This physical barrier blocks industrial ground loops and localized electrical surges from reaching the main communication network.

  • Fail-Safe Electrical Design: The module embeds internal reverse polarity protection to block wiring mishaps during installation, alongside an internal 2 A slow-blow fuse. These protection mechanisms stop component-level destruction from accidentally looping power backwards into the analog input circuit.

FAQs

  • Does this 170AAI14000 base include the terminal blocks, or do I order them separately?

    The 170AAI14000 base features two connection points built specifically for removable terminal blocks. To preserve maximum flexibility for your wiring layout, Schneider Electric packages the matching screw-type or spring-type removable terminal blocks separately. We ship this base 100% brand new in its factory box.

  • Can I mix voltage and current signals on this card simultaneously?

    Yes, but you must define the channel grouping parameters inside your network configuration software. The module hardware changes its input impedance depending on the signal type ($< 0.25\text{ Ohm}$ for 4-20mA current tracking and $> 2200\text{ kOhm}$ for voltage detection) to guarantee absolute signal linearity.

  • How fast does the processor update the analog values?

    The module refreshes all 16 channels within a 25-millisecond update cycle. This fast conversion window yields responsive data for industrial process variables like tank levels, pipe pressures, and fluid flow rates that require steady monitoring.

  • What is the proper procedure for mounting this module to maximize airflow?

    Snap the module onto a standard horizontal DIN rail inside your electrical cabinet. Because the base dissipates 5.55 W of thermal energy at full load, you must maintain standard vertical clearance above and below the module to let ambient air pass freely through the housing vents.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Remote Terminal Units: The Core of SCADA and Telemetry Systems

Understanding Remote Terminal Units: The Core of SCADA and Telemetry Systems

In industrial automation, engineers often debate the choice between a Programmable Logic Controller (PLC) and...
Read more
Ultimate Guide to Schneider Electric PLCs: Selecting Control Systems for Small to Medium Automation

Ultimate Guide to Schneider Electric PLCs: Selecting Control Systems for Small to Medium Automation

Schneider Electric remains a dominant force in global industrial automation, delivering robust control systems across diverse sectors. For control engineers, selecting the right programmable logic controller (PLC) requires balancing budget, communication ports, and processing power. This technical breakdown explores Schneider’s small and medium portfolio, offering field-tested insights to help you optimize your next factory automation project.

Read more
Essential Maintenance Guide for PLC, DCS, and ESD Marshalling Cabinets

Essential Maintenance Guide for PLC, DCS, and ESD Marshalling Cabinets

Marshalling cabinets serve as the vital interface between field instrumentation and your core control systems. In large-scale industrial automation, these panels house the intricate wiring for PLC, DCS, and Emergency Shutdown (ESD) systems. Regular, systematic health checks are non-negotiable to ensure operational reliability and prevent costly unplanned downtime.

Read more