Skip to content

What are you looking for?


You may also like

SC520 3BSE003816R1 ABB Submodule Carrier with Local CPUSC520 3BSE003816R1 ABB Submodule Carrier with Local CPUSC520 3BSE003816R1 ABB Submodule Carrier with Local CPU
SC520 3BSE003816R1 ABB Submodule Carrier with Local CPU
SC520 3BSE003816R1 ABB Submodule Carrier with Local CPU
SC520 3BSE003816R1 ABB Submodule Carrier with Local CPU

SC520 3BSE003816R1 ABB Submodule Carrier with Local CPU


Only 10 left - Selling fast

PRODUCT SKU : SC520 3BSE003816R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB SC520 3BSE003816R1, also cataloged as the SC520 Communication Module, operates as a dedicated hardware component for communication submodule hosting and local processor execution within ABB system platforms.

Hardware Specifications

Parameter Specification
Model SC520 (Order Code: 3BSE003816R1)
Brand ABB
Origin Sweden
Weight 0.742 kg
Dimensions 30 mm x 300 mm x 291 mm (W x H x D)
Operating Temp 0 to +55 deg C
Power Consumption Powered via backplane bus system
Integrated Processor Local CPU for local processing tasks
Compliance EU Directive 2011/65/EU (RoHS)
Product Type Communication Modules

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The integrated local processor on the SC520 carrier manages high-speed internal bus transfers to offload communication traffic from the main system controller. Its onboard architecture maintains firmware flash compatibility across standard ABB communication submodules, optimizing backplane bus communication velocity and preventing data bottlenecks during high-density I/O frame exchanges.

Frequently Asked Questions

Q: Is hot-swapping supported for communication submodules mounted on the SC520 carrier during active runtime?

A: No. Power to the rack chassis must be de-energized prior to inserting or removing submodules to avoid backplane communication disruption and potential board-level transients.

Q: What grounding procedure is required for the SC520 submodule carrier?

A: The carrier must be firmly latched into the card cage guide rails so that its grounding contacts make direct connection with the metallic subrack frame backplane earth.

Field Installation Guidelines

  1. Ensure power to the target subrack is fully isolated before aligning the SC520 assembly with the subrack guide slots.
  2. Slide the carrier module into the rack until the rear multipin backplane connectors seat completely into the bus socket.
  3. Tighten top and bottom retaining screws to secure physical chassis bonding and prevent vibration-induced disconnects.
  4. Verify that signal cable shielding is terminated to the cabinet protective earth (PE) bar before re-energizing the system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more