Overview

The GE Fanuc IC695CMM002 is a serial communications module for PACSystems RX3i. It provides dual-port RS232/RS422/RS485 connectivity with support for multiple industrial protocols, enabling reliable communication between controllers and field devices in automation networks.

Technical Specifications

  • Model: IC695CMM002

  • Manufacturer: GE Fanuc Emerson

  • Product Type: Serial Communications Module

  • Product Line: RX3i PACSystems

  • Number of Ports: Two (2) configurable RS232/RS422/RS485

  • Supported Protocols: MODBUS Master, MODBUS Slave, CCM Slave, DNP3 Master, DNP3 Slave, Serial I/O protocol

  • Interface Type: RJ-45 connectors

  • Selectable Baud Rates: 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K

  • Default Flow Control: Full duplex

  • Installations per Rack: Up to six modules

  • Power Requirements: 0.7 A at 3.3 VDC, 0.115 A at 5 VDC

  • Maximum Overvoltage: ±25 VDC

  • Current Rating: 0.7 mA at 3.3 VDC, 0.115 mA at 5 VDC

  • Operating Temperature: 0–60 °C (32–140 °F)

  • Data Format: 7 or 8 data bits, 1 or 2 stop bits, parity configurable (even, odd, none)

  • Status Indicators: Module OK, Port Fault, Port Status LEDs

  • Weight: 0.75 lbs (0.34 kg)

Application Scenarios

The IC695CMM002 is suitable for:

  • Establishing serial communication between RX3i controllers and field devices

  • Supporting MODBUS and DNP3 protocol networks

  • Dual-port connectivity for distributed control systems and industrial communication networks

Comparison with Similar Modules

  • IC695CMM002: Dual-port RS232/422/485, MODBUS and DNP3 support, full-duplex communication

  • IC695CMM001: Single-port RS232 module, basic serial I/O support

  • IC695CMM003: Dual-port isolated RS232/422/485 module for enhanced electrical protection

FAQs

Q: Can this module support multiple serial protocols simultaneously?
A: Yes, it can operate with MODBUS Master/Slave, DNP3 Master/Slave, CCM Slave, or Serial I/O.

Q: How many modules can be installed per rack?
A: Up to six IC695CMM002 modules can be installed per RX3i rack.

Q: Does the module provide flow control?
A: Yes, full-duplex flow control is the default setting, ensuring stable communication.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more