Skip to content

What are you looking for?


You may also like

ProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBSProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBSProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBS
ProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBS
ProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBS
ProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBS

ProSoft PROFIBUS DPV1 Slave Interface for CompactLogix | ILX69-PBS


Only 10 left - Selling fast

PRODUCT SKU : ILX69-PBS

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Module Performance Overview

The ILX69-PBS (Part Number: ILX69-PBS) is a high-speed communication gateway designed to integrate Allen-Bradley CompactLogix L1, L2, or L3 processors into a PROFIBUS DP network. Operating as a powerful DPV1 Slave, this module enables the seamless exchange of cyclic I/O data and acyclic messaging between the Rockwell Automation backplane and a PROFIBUS Master. Its primary advantage lies in the hardware-integrated protocol stack, which offloads complex communication tasks from the CPU to maintain optimal controller scan times.

Technical Specifications and Data Limits

The ILX69-PBS is engineered for high-density data environments and strict industrial timing requirements.

  • Maximum I/O Throughput: Supports up to 244 bytes of Input data and 244 bytes of Output data per scan.

  • Transmission Velocity: Automatic baud rate detection up to 12,000 kbit/s (12 Mbps).

  • Protocol Support: PROFIBUS DPV0 and DPV1 (Acyclic messaging for advanced diagnostics).

  • Backplane Compatibility: Standard 1769 CompactLogix chassis or distributed 1769 I/O racks.

  • Current Consumption: 500 mA @ 5 VDC.

  • Physical Port: Single DB9 Female connector with standard PROFIBUS pinout.

  • Weight: Approximately 1.0 kg (2.20 lbs).

  • GSD File: Required for Master-side configuration (provided by manufacturer).

Integration FAQ

How is the module configured within the Rockwell environment?Configuration is performed through the ProSoft Configuration Builder (PCB) utility. For Studio 5000 or RSLogix 5000, the module is integrated via an Add-On Profile (AOP) or by using a generic module profile with provided Add-On Instructions (AOI) to map I/O data to controller tags.

Does the module require an external power supply?No, the ILX69-PBS draws its operating power directly from the 1769 backplane. However, the PROFIBUS cable itself should be properly terminated at both ends of the segment to ensure signal integrity at high baud rates.

Application Scenarios

The ILX69-PBS is frequently deployed in hybrid manufacturing plants where an Allen-Bradley CompactLogix system must report to a Siemens-based PLC or a larger PROFIBUS-controlled SCADA network. It is ideal for high-speed motion synchronization and complex instrumentation data harvesting.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Siemens Interface Modules (IM): The Backbone of Distributed I/O

Mastering Siemens Interface Modules (IM): The Backbone of Distributed I/O

In the realm of industrial automation, efficiency depends on how effectively a system communicates with its peripherals. The Siemens Interface Module (IM) serves as the critical link in this architecture. It enables seamless data exchange between centralized controllers and decentralized hardware. Whether you are working with the S7-300, S7-1500, or ET 200 series, understanding the IM is essential for modern control systems.

Read more
Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Dynamic Data Exchange (DDE) remains a vital legacy protocol for industrial communication. Originally for general computing, it now bridges the gap between factory floor data and enterprise reporting. This enduring method provides a foundational link for integrating real-time software layers in modern industrial automation.

Read more
Master FIFO and LIFO Sequences for Advanced PLC Logic

Master FIFO and LIFO Sequences for Advanced PLC Logic

In industrial automation, managing data flow is as critical as hardware control. This guide explores how FIFO and LIFO sequential logic can optimize your control systems. Master these essential tools to build more efficient sorting, inventory tracking, and data management workflows for any modern factory.

Read more