Skip to content

What are you looking for?


You may also like

ProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface ModuleProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface ModuleProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface Module
ProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface Module
ProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface Module
ProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface Module

ProSoft | MVI46-MNET | Allen Bradley | Modbus TCP/IP Interface Module


Only 10 left - Selling fast

PRODUCT SKU : MVI46-MNET

PRODUCT TYPE : Modbus TCP/IP Interface Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MVI46-MNET module from ProSoft Technology is a Modbus TCP/IP communication interface designed for Allen Bradley PLC systems. It enables seamless integration between ControlLogix controllers and Modbus TCP/IP devices, supporting multiple client and server connections with robust memory mapping and diagnostic features.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: MVI46-MNET

  • Part Number: MVI46-MNET

  • Product Type: Modbus TCP/IP Interface Module

  • Category: PLCs

  • Product Line: ControlLogix

  • Weight: 3.00 lbs (1.36 kg)

  • Protocol: Modbus TCP/IP

  • Connections: 5 MBAP / 5 MNET supported

  • Port: 1 × RJ45 Ethernet

  • Memory Mapping: 5000 × 16-bit registers

  • Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC

  • LED Indicators: Yes (status and diagnostics)

  • Operating Temperature: 0–40°C (32–104°F)

Core Features

  • Provides Modbus TCP/IP connectivity for ControlLogix systems

  • Supports multiple simultaneous client and server connections

  • Large register capacity for complex data mapping

  • Compact single-slot design for easy installation

  • Integrated LED indicators for diagnostics and monitoring

Application Scenarios

  • Integration of Modbus TCP/IP devices into ControlLogix PLC systems

  • SCADA and distributed control systems requiring Modbus communication

  • Industrial automation setups needing reliable Ethernet-based connectivity

FAQ

  • Q: How many connections does the MVI46-MNET support?  A: It supports up to 5 MBAP and 5 MNET connections simultaneously.

  • Q: What is the maximum register capacity?  A: The module supports up to 5000 × 16-bit registers.

  • Q: Does the module provide diagnostic indicators?  A: Yes, LED indicators are included for module and communication status.

Comparison with Similar Modules

  • MVI69-MNET: Modbus TCP/IP module for CompactLogix systems.

  • MVI56E-MNETCR: Enhanced multi-client Modbus TCP/IP module for ControlLogix systems.

  • PLX32-EIP-MBTCP: Gateway module for EtherNet/IP to Modbus TCP/IP communication.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more