Overview

The ABB PM858K01 (3BSE082895R1) is a high-performance processor unit for the AC 800M control system, built around an MPC866 microprocessor. It supports complex automation applications with fast task execution, redundancy options, and integrated communication interfaces. Designed for precision and reliability, this unit delivers efficient control performance in distributed and process automation systems.

Core Features

  • Processor Type: MPC866

  • Clock Synchronization: 1 ms accuracy across AC 800M controllers via CNCP protocol

  • Redundant Configuration: Switch-over time ≤10 ms

  • Applications per Controller: Up to 32

  • Programs per Application: 64

  • Diagrams per Application: 128

  • Cycle Times: Up to 32 individual cycle settings, as fast as 1 ms per program

  • Flash Memory for Firmware: 4 MB

  • Backup Battery: Integrated 3.6 V lithium cell

  • Power Supply: 24 V DC (range 19.2–30 V DC)

  • Power Consumption: 210 mA typical, 360 mA maximum

  • Power Dissipation: 5.1 W typical, 8.6 W maximum

  • Redundant Power Supply Input: Supported

Communication and Networking

  • Ethernet Ports: 2 × RJ-45, IEEE 802.3, 10 Mbit/s

  • Control Network Protocols: MMS (Manufacturing Message Service), IAC (Inter Application Communication)

  • Recommended Network Backbone: 100 Mbit/s switched Ethernet

  • Transmission Speed to OPC Server: 36–86 events/sec and 113–143 data messages/sec

  • Event Queue Capacity: Up to 3000 events per OPC client

  • RS-232C Interfaces:

    • Two general ports (COM3 and COM4), with baud rates from 75 to 19,200

    • COM3 supports full RTS/CTS

    • COM4 is optically isolated

  • Comm. Modules on CEX Bus: Up to 12

  • CEX Bus Current Supply: Max 2.4 A

I/O and System Integration

  • I/O Clusters with Non-Redundant CPU: 1 electrical + 7 optical

  • I/O Clusters with Redundant CPU: 7 optical

  • Maximum ModuleBus I/O Capacity: 96 modules (single CPU) or 84 modules (redundant setup)

  • ModuleBus Scan Rate: 0–100 ms (depending on module count)

  • Electrical ModuleBus Supply:

    • 24 V: max 1.0 A

    • 5 V: max 1.5 A

  • Real-Time Clock Stability: 100 ppm (≈1 hour/year drift)

Application Scenarios

The PM858K01 is ideal for:

  • Distributed control systems requiring high reliability and redundancy

  • Large-scale process automation in oil, gas, and power generation plants

  • Multi-application architectures needing fast cycle times and deterministic communication

FAQ

Q: What distinguishes the PM858K01 from PM856A and PM860K01?
A: The PM858K01 offers faster processing, more I/O capacity, and shorter switch-over times than the PM856A, while maintaining comparable reliability to the PM860K01 in redundant configurations.

Q: Can PM858K01 operate without redundancy?
A: Yes, it supports both single and redundant configurations, providing flexibility for system design.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more