Overview

The 1785-L40C15 is an Allen-Bradley PLC-5/40 processor designed for high-performance ControlNet communications. Engineered for industrial automation, it provides robust program memory and extensive I/O capacity, making it suitable for complex control applications.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Part Number: 1785-L40C15

  • Product Type: PLC-5/40 Processor Module

  • Processor Type: PLC-5/40

  • Communication Network: ControlNet

  • Program Memory: Up to 48K words (model-dependent)

  • Maximum I/O Capacity: 2048 points (inputs and outputs combined, free mode)

  • Communication Ports:

    • Serial

    • Data Highway Plus (DH+)

    • DH via 1785-KA Adapter

    • Remote I/O (RIO)

    • ControlNet embedded ports

  • Dimensions: 4.9 x 16.5 x 27.4 cm

  • Weight: 1.42 kg

  • Mounting: Standard DIN rail or panel installation

Features

  • High-capacity memory for complex PLC-5 programs

  • Extensive I/O support for large industrial systems

  • Embedded multi-protocol communication for flexibility

  • Reliable ControlNet performance for real-time applications

  • Compact design for easy integration into control panels

Applications

  • Large-scale industrial automation requiring high I/O

  • Factory floor control systems with real-time data requirements

  • Integration with remote I/O and Data Highway networks

FAQ

Q: Can 1785-L40C15 work with older PLC-5 modules?
A: Yes, it supports backward compatibility with previous PLC-5 I/O modules using DH+ or RIO.

Q: What is the maximum program memory?
A: Up to 48K words depending on model revision.

Q: Is ControlNet required to operate this processor?
A: No, it supports multiple communication protocols including DH+ and RIO, but ControlNet provides optimal high-speed performance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more