Skip to content

What are you looking for?


You may also like

PanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI TerminalPanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI TerminalPanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI Terminal
PanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI Terminal
PanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI Terminal
PanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI Terminal

PanelView 800 2711R-T7T Allen-Bradley 7" Touch HMI Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711R-T7T

PRODUCT TYPE : HMI

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The 2711R-T7T is an Allen-Bradley PanelView 800 series human-machine interface (HMI) designed to provide clear visualization and reliable operator control in industrial automation applications. It combines a widescreen TFT LCD with responsive touchscreen input and multiple communication options.

Technical Specifications

  • Brand & Model: Allen-Bradley 2711R-T7T

  • Product Line: PanelView 800

  • Product Type: Human-Machine Interface (HMI)

  • Display Size: 7 inches

  • Display Type: Color transmissive TFT active matrix LCD, widescreen format

  • Resolution: 800 x 480 pixels

  • Display Area: 153.6 x 86.6 mm (6.05 x 3.41 in)

  • Touchscreen: Analog resistive, 1 million presses rated

  • Backlight Lifetime: 40,000 hours

  • Input Type: Touchscreen

  • Integrated Ports: Ethernet, RS-232, RS-422/485, USB

  • Memory: 256 MB Flash; 256 MB DDR RAM

  • Input Voltage Range: 18–32 VDC

  • Input Power: 24V DC

  • Operating Series: A

  • Heat Dissipation: 34 BTU/hour

Features

  • Widescreen color display with clear graphics

  • Multi-protocol communication: Ethernet, serial

  • Long-life backlight for extended use

  • Compact, panel-mounted design

Applications
Suitable for factory floor automation, machine monitoring, and process control applications requiring reliable operator interaction.

FAQ

Q: What type of touchscreen does the 2711R-T7T use?
A: It uses an analog resistive touchscreen, rated for 1 million presses.

Q: What communication options are available?
A: The HMI supports Ethernet, RS-232, RS-422/485, and USB connectivity.

Q: What is the expected lifetime of the backlight?
A: Approximately 40,000 hours of operation under normal conditions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more