Skip to content

What are you looking for?


You may also like

NTA16-A | ABB | Medium-Voltage Circuit BreakerNTA16-A | ABB | Medium-Voltage Circuit BreakerNTA16-A | ABB | Medium-Voltage Circuit Breaker
NTA16-A | ABB | Medium-Voltage Circuit Breaker
NTA16-A | ABB | Medium-Voltage Circuit Breaker
NTA16-A | ABB | Medium-Voltage Circuit Breaker

NTA16-A | ABB | Medium-Voltage Circuit Breaker


Only 10 left - Selling fast

PRODUCT SKU : NTA16-A

PRODUCT TYPE : Vacuum Circuit Breakers

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB NTA16-A, also cataloged as the NTA16-A Medium-Voltage Vacuum Circuit Breaker, operates as a dedicated hardware component for high-current fault interruption and electrical circuit isolation within medium-voltage distribution networks.

Hardware Specifications

Parameter Specification
Model NTA16-A
Brand ABB
Origin Switzerland
Weight 500 g
Dimensions 1200 mm x 800 mm x 500 mm
Operating Temp -25 to +40 deg C standard industrial range
Power Consumption Dependent on motor charging and trip/close coil actuation
Voltage Rating 12 kV
Current Rating 1600 A
Interrupting Rating 40 kA
Operating Mechanism Spring-operated
Closing Time Less than 3 cycles
Trip Time Less than 1 cycle
Interruption Medium Vacuum

Profinet / EtherNet/IP Deterministic Networks

When integrated with digital control interfaces, the ABB NTA16-A relays auxiliary contact states, spring charge signals, and trip alarms to supervisory systems across Profinet / EtherNet/IP deterministic networks. This continuous data streaming tracks opening and closing mechanical propagation times, allowing the central logic controller to detect synchronization discrepancies. The high-speed network transmission interface supports predictable telemetry throughput times, minimizing latency in supervisory control and data acquisition loops while ensuring that device status parameters correspond accurately with the localized control room database files.

Frequently Asked Questions

Q: How do the trip and close coil circuits maintain communication velocity with industrial controllers during a fault event?

A: The physical trip and close coils operate via direct binary hardware interlocks. Auxiliary contacts echo the physical state back to network gateways, which package the breaker open/close flags into high-priority communication packets to maintain sub-millisecond status update transmission times.

Q: What are the impacts of firmware flash compatibility on the electronic control and protection units connected to this breaker?

A: The internal spring charging motor and manual trip assemblies function independently of any software. However, the microprocessors in accompanying external protection relays require exact firmware version alignment to ensure precise time-stamping of the less than 1 cycle trip sequence data.

Field Installation Guidelines

  1. Position the 500 g structure using heavy-duty mechanical hoisting apparatus rated specifically for the physical footprint dimensions.
  2. Align the primary copper draw-out stabs or terminal bars, applying industrial contact grease to ensure uniform current distribution across the 1600 A interface.
  3. Secure the auxiliary low-voltage control harness, verifying that the physical wiring remains isolated from high-voltage electromagnetic interference paths.
  4. Verify the integrity of the station ground network connection by bonding the main chassis grounding pad directly to the switchgear earth bus using the specified torque values.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more