Skip to content

What are you looking for?


You may also like

MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HARTMU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HARTMU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART
MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART
MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART
MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART

MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART


Only 10 left - Selling fast

PRODUCT SKU : MU/MC-TAIH12 51304337-100

PRODUCT TYPE : Smart Transmitter Interface

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell MU/MC-TAIH12 (51304337-100) Smart Transmitter Interface is designed to integrate intelligent field transmitters into industrial automation systems. Supporting HART communication, it enables seamless digital data exchange while maintaining analog signal compatibility. With fast response times and robust design, this interface ensures reliable performance in demanding environments.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: MU/MC-TAIH12

  • Order/Part Number: 51304337-100

  • Product Type: Smart Transmitter Interface

  • Power Supply: 24 VDC

  • Operating Temperature: –40 °C to +85 °C

  • Communication Protocol: HART

  • Input Impedance: 250 Ω

  • Response Time: <1 second

Application Scenarios

  • Integration of HART-enabled smart transmitters in distributed control systems (DCS)

  • Oil & gas process monitoring and control

  • Chemical processing plants requiring precise transmitter communication

  • Power generation and manufacturing automation systems

FAQ

Q: What is the advantage of HART communication in MU/MC-TAIH12?  
A: HART allows digital communication over existing analog wiring, enabling advanced diagnostics and configuration without additional infrastructure.

Q: Can this interface be used with non-HART transmitters?  
A: Yes, it supports analog signals, but full functionality is achieved with HART-enabled devices.

Q: How fast is the response time?  
A: The module responds in less than one second, ensuring timely data acquisition for process control.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more