Skip to content

What are you looking for?


You may also like

MDK1*B Yokogawa Communication PCB BoardMDK1*B Yokogawa Communication PCB BoardMDK1*B Yokogawa Communication PCB Board
MDK1*B Yokogawa Communication PCB Board
MDK1*B Yokogawa Communication PCB Board
MDK1*B Yokogawa Communication PCB Board

MDK1*B Yokogawa Communication PCB Board


Only 10 left - Selling fast

PRODUCT SKU : MDK1*B

PRODUCT TYPE : Communication Boards

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa MDK1*B, also cataloged as the MDK1 Communication PCB Board, operates as a dedicated hardware component for data processing and signal interface routing within Yokogawa CENTUM control system networks.

Suffix Breakdown & Model Matrix

Code Element Specification / Description
MDK1 Base model designation for industrial control communication board series
*B Style code Revision B specifying physical circuit layout, component footprint, and terminal interface assembly

Hardware Specifications

Parameter Specification
Model MDK1*B
Brand Yokogawa
Origin Japan
Weight 0.4 kg
Dimensions 13.00 cm x 12.50 cm x 8.00 cm
Operating Temp 0 deg C to 55 deg C
Storage Temp -20 deg C to 70 deg C
Relative Humidity 5% to 95% RH (non-condensing)
Power Supply 24 VDC
Power Consumption 5 W
Core Function Communication and data processing execution

Channel-to-Channel Isolation and DCS Signal Integration

The MDK1*B communication board processes high-speed data exchanges across the internal DCS backplane. Built-in channel-to-channel galvanic isolation decouples individual signal paths, suppressing ground loop currents and filtering common-mode electrical noise across field loops. The board routes 4-20 mA HART loop protocol data and discrete digital states into system registers, ensuring signal integrity between distributed I/O nodes and central processor units.

Frequently Asked Questions

Q: Does the MDK1*B board support online hot-swapping during active system operation?

A: Module insertion or removal must be conducted while the target rack segment is de-energized, unless installed within a designated redundant communication slot, to prevent transient backplane disruptions.

Q: How does internal isolation protect signal processing logic on the MDK1*B board?

A: Embedded channel-to-channel isolation barriers decouple field-side wiring loops from internal micro-logic circuits, preventing ground potential differentials from damaging adjacent channels.

Q: What power parameters are required to run the MDK1*B board?

A: The board operates on a regulated 24 VDC power supply rail, drawing a maximum continuous power load of 5 W under full processing operation.

Field Installation Guidelines

  1. Board Mounting: Align the PCB card edges with the guide rails of the designated rack slot. Slide the MDK1*B board inward until the rear backplane connector fully seats into the chassis socket.
  2. Power Supply Checks: Verify that the incoming power supply is stabilized at 24 VDC prior to energizing the rack assembly.
  3. Cable Shielding: Connect all communication cable shielding drain wires directly to the cabinet functional earth (FE) ground bar at a single termination point to prevent noise loops.
  4. Thermal Clearance: Maintain unobstructed ventilation space above and below the card cage to allow free air convection, keeping operating ambient temperatures within 0 deg C to 55 deg C.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evaluating Industrial Automation: Architectural Benefits and Operational Challenges

Evaluating Industrial Automation: Architectural Benefits and Operational Challenges

Modern manufacturing relies heavily on advanced industrial automation to streamline production cycles and maintain precise process execution. Automated control systems, programmable logic controllers (PLCs), and distributed control systems (DCS) replace repetitive manual intervention on shop floors. Evaluating the balance between operational gains and capital investment remains essential for engineering leaders planning smart factory upgrades.

Read more
Strategic Emergency Shutdown Button Installation: Securing Industrial Gas Pipelines

Strategic Emergency Shutdown Button Installation: Securing Industrial Gas Pipelines

Emergency Shutdown (ESD) systems serve as the critical last line of defense in power plants and chemical facilities. Plant engineers frequently install manual ESD pushbuttons at boundary fence lines near gas pipeline entry points. Positioning safety devices far from main generation units ensures fast isolation and protects personnel during major gas releases.

Read more
Multi-Touch HMI Technology: Transforming Interaction in Industrial Automation

Multi-Touch HMI Technology: Transforming Interaction in Industrial Automation

Modern human-machine interfaces (HMIs) are evolving rapidly across factory floors worldwide. Traditional resistive touchscreens allowed operators to register only a single touch point at a time. Today, multi-touch HMI panels enable intuitive multi-finger gestures and concurrent multi-operator inputs in demanding industrial automation setups.

Read more