Skip to content

What are you looking for?


You may also like

KL3106X1-BA1 DeltaV Process Controller Module | EmersonKL3106X1-BA1 DeltaV Process Controller Module | EmersonKL3106X1-BA1 DeltaV Process Controller Module | Emerson
KL3106X1-BA1 DeltaV Process Controller Module | Emerson
KL3106X1-BA1 DeltaV Process Controller Module | Emerson
KL3106X1-BA1 DeltaV Process Controller Module | Emerson

KL3106X1-BA1 DeltaV Process Controller Module | Emerson


Only 10 left - Selling fast

PRODUCT SKU : KL3106X1-BA1

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Emerson KL3106X1-BA1, also cataloged as the KL3106X1-BA1 Intrinsically Safe RTD / Resistance input CHARM, operates as a dedicated hardware component for low-voltage resistance signal acquisition within DeltaV electronic marshalling subsystems. This unit interfaces directly with resistance temperature detectors (RTDs) and ohmic instruments located in hazardous environments, executing direct down-loop signal conditioning and digitizing physical temperatures into process data blocks over the system backplane network.

Hardware Specifications

Parameter Specification
Model KL3106X1-BA1
Brand Emerson
Origin U.S.A.
Weight 0.08 kg
Dimensions Standard CHARM module footprint slot width
Operating Temp -40 deg C to +70 deg C
Power Consumption +6.3 VDC at 0 mA (CHARM Bus), +24 VDC at 23 mA (Field Circuit)
Input Signal Types RTD (Resistance Temperature Detector), Ohmic Resistance variables
Shock Resistance 10g 1/2 sine wave for 11 ms
Vibration Resistance 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz
Airborne Contaminants ISA-S71.04-1985 Class G3 compliance
Relative Humidity 5% to 95% non-condensing
Terminal Block Key Position E6

Channel-To-Channel Isolation and RTD Processing

Mechanical execution of this baseplate-mounted component relies on galvanic separation barriers to maintain thermal measurement reliability. The module architecture features high-precision analog-to-digital conversion parameters linked with active channel-to-channel isolation. This electrical boundary safeguards the sensitive measurement circuitry, ensuring that ground fault currents, common-mode noise, or localized voltage transients on an active field RTD wiring track cannot distort data values or introduce resistance offsets on neighboring signal channels.

Frequently Asked Questions

Q: Does this intrinsically safe RTD module support hot-swap replacement while the baseplate is powered?

A: Yes. The hardware configuration enables real-time hot-swap procedures without disrupting adjacent active terminal points. Internal current-limiting components suppress electrical backplane bus disturbances and diagnostic glitches during a live module exchange.

Q: What is the technical function of the E6 mechanical key position?

A: The E6 mechanical keying assignment physically prevents an incorrect or non-matching characterization module type from being inserted into a terminal slot wired for this resistance input configuration, preventing high-voltage loops from damaging the low-voltage sensor circuit.

Field Installation Guidelines

  • Baseplate Slot Insertion: Align the rear terminal guides of the CHARM module perpendicularly with the designated baseplate receptor. Press downward until the dual mechanical retention latches click completely into place to ensure uniform electrical tracking.

  • Intrinsically Safe Wiring Separation: All resistance sensor cables originating from hazardous areas must run through segregated blue wiring ducts. Maintain a minimum distance of 50 mm between intrinsically safe paths and standard non-intrinsically safe power infrastructure.

  • Shield Ground Maintenance: Terminate RTD extension wire shields exclusively at the carrier grounding bar assembly. Implementing a strict single-point grounding layout prevents common-mode noise generation across the sensitive resistance sensor tracks.

  • Environmental Control Parameters: For installation sites containing Class G3 airborne contaminants, the marshalling enclosure must maintain a continuous positive-pressure air flow and keep relative humidity below the 95% non-condensing limit to protect active terminal contacts from chemical degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more